Viessmann VITODENS 242-F Installation And Service Instructions Manual page 118

3.2 to 26 kw gas condensing/solar storage combi boiler gas council no. 41-819-18; 41-819-19 natural gas and lpg version
Table of Contents

Advertisement

Code 2
"Heating circuit ..."
Coding in the delivered condition
Note
Observe settings of cod-
ing addresses "3A", "3b"
and "3C" in group "Gen-
eral", and "d5" and "d8"
in group "Heating cir-
cuit...".
F8:–5
Temperature limit for ter-
minating reduced mode
–5 °C, see example on
page 165.
Observe the setting of
coding address "A3".
F9:–14
Temperature limit for rais-
ing the set reduced room
temperature –14 °C, see
example on page 165.
FA:20
Raising the set boiler wa-
ter or flow temperature by
20 % when changing
from operation with re-
duced room temperature
to operation with stand-
ard room temperature.
See example on
page 166.
Fb:60
Duration of the set boiler
water or flow temperature
rise (see coding address
"FA") 60 min. See exam-
ple on page 166.
118
(cont.)
Possible change
F2:12
F8:+10
to
F8:–60
F8:–61
F9:+10
to
F9:–60
FA:0
to
FA:50
Fb:0
to
Fb:300
Temperature limit adjusta-
ble from
+10 to –60 °C
Function disabled
Temperature limit for rais-
ing the set room tempera-
ture to the value selected
for standard mode adjusta-
ble from
+10 to –60 °C
Temperature rise adjusta-
ble from 0 to 50 %
Duration adjustable from 0
to 300 min.