Viessmann VITODENS 242-F Installation And Service Instructions Manual page 102

3.2 to 26 kw gas condensing/solar storage combi boiler gas council no. 41-819-18; 41-819-19 natural gas and lpg version
Table of Contents

Advertisement

Code 2
"General"
(cont.)
Coding in the delivered condition
53:1
Function connection sK
of the internal extension:
DHW circulation pump
54:3
Do not adjust
6E:50
No display correction for
outside temperature.
76:0
Without LON communi-
cation module
77:1
LON subscriber number
79:1
With LON communication
module:
Control unit is fault man-
ager (only for weather-
compensated control
units)
7b:1
With LON communication
module:
Control unit transmits the
time (only for weather-
compensated control
units)
7F:1
Detached house
80:6
A fault message is dis-
played if a fault is active
for at least 30s
102
Possible change
53:0
Central fault message
53:2
External heating circuit
pump (heating circuit 1)
53:3
External circulation pump
for cylinder heating
6E:0
Display correction –5 K
to
to
6E:49
Display correction –0.1 K
6E:51
Display correction +0.1 K
to
to
6E:99
Display correction +4.9 K
76:1
With LON communication
module (automatic recog-
nition)
77:2
LON subscriber number,
to
adjustable from 1 to 99:
77:99
1 - 4 = Boiler
5 = Cascade
10 - 97 = Vitotronic 200-H
98 = Vitogate
99 = Vitocom
79:0
Control unit is not fault
manager
7b:0
Does not transmit time
7F:0
Apartment building
Holiday program and time
program for DHW heating
can be set separately
80:0
Immediate fault message