Viessmann FB2B Installation And Service Instructions Manual page 106

4.8 to 26 kw gas condensing/solar storage combi boiler natural gas and lpg version gas council no.: 47-819-18 19 kw 47-819-19 26 kw
Table of Contents

Advertisement

Troubleshooting
Fault codes
(cont.)
Displayed
System characteris-
fault code
tics
A4
Control mode
A7
Control mode as per
delivered condition
A8
Burner blocked. The
venting program is
started automatically
(see page 66)
A9
The burner operates
at its lower output if a
heating circuit with
mixer is connected.
The burner is blocked
if only one heating cir-
cuit without mixer is
connected.
b0
Burner blocked
b1
Control mode as per
delivered condition
b4
Regulates as if the
outside temperature
was 0 °C
b5
Control mode as per
delivered condition
b7
Burner blocked
106
Cause
Measures
Max. system pres-
Check system pressure.
sure exceeded
Check the function and
sizing of the diaphragm
expansion vessel.
Vent the heating system.
Coding address "0E"
(group boiler/1) is set to
"1" to document the fault.
After the fault has been
removed, reset manually
to "0".
Programming unit
Replace programming
faulty
unit
Air lock in the inter-
Vent the system if the fault
nal circulation
message continues to be
pump or minimum
displayed
flow rate not ach-
ieved
Internal circulation
Check the circulation
pump blocked
pump
Short circuit, flue
Check the flue gas tem-
gas temperature
perature sensor
sensor
Communication
Check connections and
error, program-
replace the programming
ming unit
unit if required
Internal fault
Replace the control unit
Internal fault
Replace the control unit
Boiler coding card
Plug in boiler coding card
faulty
or replace, if faulty