Vertical Blade ASSYs

12.Vertical Blade ASSYs
Warning
Step
Unfasten the 3 hooks at
1
the shaft mounting part
by pressing them with a
flat screwdriver.
2
Unfasten the hooks at
the upper 2 positions
with a flat screwdriver.
3
Remove the vertical
blade ASSY.
22
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
Vertical blade ASSY
Points
A vertical blade ASSY has 6
fins. It is impossible to
replace only one fin.
The vertical blade ASSY is
not marked for difference
between right and left.
(R12154)
(R12155)
(R12156)
Removal Procedure
Si041256