Daikin CTXG25K2VMW Service Manual page 20

2.5/3.5/5.0 kw class
Table of Contents

Advertisement

Indoor Heat Exchanger
Step
2. Remove the indoor unit.
Detach the indoor unit
1
from the installation
plate.
3. Remove the indoor heat
exchanger.
Unfasten the hook of
1
the piping fixture at the
back of the indoor unit
and pull out the pipe.
Slightly widen the
2
auxiliary pipe.
3
Remove the 2 screws
on the left side of the
unit.
18
Procedure
Installation
plate
Piping fixture
Points
(R12142)
(R12143)
(R12144)
(R12145)
Removal Procedure
Si041256