Disposal Requirements - Foster BCT Series Original Operation Instructions

Cabinets, touchpad controller
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
GB
Important Note to the Installer:
Please ensure that this document is passed to the user as it
contains important guidelines on operation, loading, cleaning and
general maintenance and should be kept for reference.
General Electrical Safety
Foster Refrigerator recommends that the equipment is electrically connected via a Residual Current Device; such
as a Residual Current Circuit Breaker (RCCB) type socket, or through a Residual Current Circuit Breaker with
Overload Protection (RCBO) supplied circuit.

Disposal Requirements

If not disposed of properly all refrigerators have components that can be harmful to the environment. All old
refrigerators must be disposed of by appropriately registered and licensed waste contractors, and in accordance
with national laws and regulations.
Start-Up and Operation
After unpacking, clean and allow the cabinet to stand for 2 hours before turning on (cleaning directions
supplied within this manual). Ensure the cabinet is situated where neither hot nor cold air sources will affect its
performance. Make sure that a minimum clearance of 150mm around the cabinet is available for ventilation and
effective operation. There is no minimum clearance for above the cabinets. Connect the unit to a suitable mains
power outlet and turn the supply on.
BCT52-26 require a 16amp supply. The BFT52 is the only model that requires a 3 phase supply.
Do not plug or unplug the unit with wet hands.
Initialisation screen
After power is applied to the
unit the controller display
will show the initialisation
screen. This will only show
for a few minutes stating
both 'Booting' and then
displaying the software
version at the bottom of the
screen. When the controller
has completed initialisation the screen will revert to the
'Home Screen'.
Touchpad Icons
Chill Cycle Symbol
Cycle Progression Bar
Detail Information
(Some icons or switches are only visible during adjustment, when activated by parameters or through operation/manual
Please note that while most of the models are 13amp supply the BFT38 and
Cycle Description
Stop Button
Home Screen
This is shown after
initialisation and when no
programmes are running.
From this page a cycle can
be launched. Select the
cycle type by pressing the
relevant cycle button and
then press 'Start'. This page
also shows the date, time
and current air temperature and allows access to the
'Settings Home Page' and 'Information' function.
Time Elapsed
Air (T1) Temperature
selection).
Day & Current Time
Surround Signal
Information Button
2