Zte Alarm Box User Manual page 44

Table of Contents

Advertisement

Alarm Box User Manual
5.4.1.4 cfgTcpComm
Command
cfgTcpComm
Function
The alarm box can be simultaneously connected to 10 groups of alarm servers.
If the alarm box interacts with an alarm server through TCP, you need to set up
a TCP connection between the alarm box and the server by using the
cfgTcpComm command.
Format
cfgTcpComm [Sequence] [Server IP] [Port] [Group ID]
Parameter Description
Example
601> cfgTcpComm 1 195.152.115.129 5000 1
Port0
= 5000
ServerIp0 = 195.152.115.129
Groupid0=1
Link0State:Active
************************************************************
Parameter
Sequence
Server IP
Port
Group ID
************************************************************
TcpServer1 Set succeed !!!
************************************************************
(TCP Port)
(IP address of the alarm server)
(Group that the server belongs to)
(Link status)
Description
Indicates the sequence number of the alarm
number. The value ranges from 0 to 63.
Indicates the IP address of the alarm server.
Indicates the TCP port configured on the alarm
server.
Indicates the ID of the group that the alarm server
belongs to. The value ranges from 1 to 10.
5-6

Advertisement

Table of Contents
loading

Table of Contents