Auxiliary power supply data

3-phase fused output from the mains +G429

Voltage
Frequency
Protection
Max. conductor size (0X12)
Allowed electrical system
Overvoltage category
(IEC 62109, IEC 60664-1)

Control unit connection data (BCU-12)

Control panel type

ACS-AP-I

Protection classes

Protection class
Degrees of protection
Protective class (IEC 62109-1) I
Overvoltage category (IEC
62109-1)
Environmental category

Efficiency

The efficiency values are valid without auxiliary power consumption. The inverter complies
with efficiency standards IEC 61683 and EN 50530.
Note: Inverter efficiency cannot be calculated from inverter software parameter values.
DC voltage
PVS800-57B-1645kW-C
DC voltage
PVS800-57B-1732kW-C
DC voltage
PVS800-57B-1645kW-C
DC voltage
PVS800-57B-1732kW-C
380/400 V AC depending on the voltage class of the inverter
50/60 Hz
IEC:
32 A gG type fuses (option +G429)
2
50 mm
/AWG 1/0
IT (ungrounded) system
OVC III
Refer to
Control unit
on page 73.
Refer to ACS-AP-x assistant control panels user's manual
(3AUA0000085685 [English])
Classification
(1
IP41
OVC II PV and OVC III Mains
Indoor conditioned
Maximum efficiency
550 V
98.5
580 V
98.5
European efficiency
550 V
98.3
580 V
98.4
590 V
700 V
98.2
97.9
620 V
715 V
98.3
98.0
590 V
700 V
98.0
97.6
620 V
715 V
98.1
97.7
Technical data 55
765 V
800 V
97.7
97.5
765 V
800 V
97.8
97.7
765 V
800 V
97.4
97.2
765 V
800 V
97.5
97.4