Siemens SITRANS L Series Operating Instructions Manual page 34

Point level switches
Hide thumbs Also See for SITRANS L Series:
Table of Contents

Advertisement

Connecting
5.6 SITRANS LVS200 Pipe extension version
Version with 1" (ANSI B 1.20.1.) NPT thread
32
Pipe length x
LVS200 (7ML5733 with short fork, application type 2, liquids/solids interface): X = L - 190 mm (X
= L - 7.5")
LVS200 (7ML5733 with standard fork, application type 1): X = L - 260 mm (X = L - 10.2")
LVS200 (7ML5733 with standard fork, application type 1 and z option K05 or G01, enhanced
sensitivity): X = L - 285 mm (X = L - 11.2")
Note: L is the total extension length
Free from burrs
Thread 1" NPT ANSI B 1.20.1
Effective thread length: 17.3 +2 mm (0.68 +0.08") (dimension L2 according to standard ANSI B
1.20.1)
SITRANS LVS100/200
Operating Instructions, 01/2019, A5E44839609-AA