Fitness for use
Some creep tests have been conducted in accordance with ETAG guideline 001 part 5 and TR 023 in the following
conditions : in dry environnement at 50 °C during 90 days.
These tests show an excellent behaviour of the post-installed connection made with HIT-RE 500: low
displacements with long term stability, failure load after exposure above reference load.
Resistance to chemical substances
Categories
Alkaline products
Acids
Solvents
Products from job site
Environnement
Electrical Conductivity
HIT-RE 500 in the hardened state does not conduct electrically. Its electric resistivity is 66 10
(DIN IEC 93 – 12.93). It is adapted well to realize electrically insulating anchorings (ex: railway applications,
subway).
09 / 2014
Chemical substances
Drilling dust slurry pH = 12,6
Potassium hydroxide solution (10%) pH = 14
Acetic acid (10%)
Nitric acid (10%)
Hydrochloric acid (10%)
Sulfuric acid (10%)
Benzyl alcohol
Ethanol
Ethyl acetate
Methyl ethyl keton (MEK)
Trichlor ethylene
Xylol (mixture)
Concrete plasticizer
Diesel
Engine oil
Petrol
Oil for form work
Sslt water
De-mineralised water
Sulphurous atmosphere (80 cycles)
These pages are part of the Anchor Fastening Technology Manual issue September 2014
Hilti HIT-RE 500 mortar w/
rebar (as post-installed conn.)
resistant
Non resistant
+
+
+
+
+
+
+
+
+
+
+
12
.m
+
+
+
+
+
+
+
+
+
915