Removal Of Fan Guards / Electrical Box - Daikin FTXG25JV1BW Service Manual

Removal procedure 2.5/3.5 kw class, indoor unit, inverter, wall mounted type, heat pump
Hide thumbs Also See for FTXG25JV1BW:
Table of Contents

Advertisement

Removal of Fan Guards / Electrical Box

7. Removal of Fan Guards / Electrical Box
Procedure
Step
1. Remove the fan guards.
1
Unfasten the 2 hooks
and remove the fan
guard.
2. Remove the electrical
box.
1
Remove the screw and
remove the drip proof
plate.
Remove the screw and
2
release the earth wire.
Pull out the indoor heat
exchanger thermistor.
16
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Fan guard
Drip proof plate
Indoor heat exchanger thermistor
Earth wire
Points
Use a sharp tool such as an
awl to unfasten the lower
hooks.
(R12110)
Preparation
Remove the front grille
according to the "Removal of
Front Grille".
(R15283)
(R12112)
Removal Procedure
Si041058