Eventia Suite (SmartEvent and Reporter Suite): Configure Smart-1 as a dedicated server for
SmartEvent, and no other Software Blade. SmartEvent and Reporter Suite contains SmartReporter
Server, SmartEvent Server, and SmartEvent Correlation Unit.
Security Management
If you choose to install a Security Management server, in the Security Management page:
Primary Security Management is the Security Management server that will normally be active. To set
up a Security Management server in a non-Management HA deployment, choose this option. In a
Management HA deployment, if the Primary Security Management server fails, the Secondary Security
Management server takes over.
Secondary Security Management is the Security Management server that takes over if the Primary
Security Management server fails. This option applies only in a Management HA deployment.
Log Server is the repository for log entries generated on gateways. Check Point gateways send their
log entries to the Log Server.
SmartEvent and SmartReporter Suite Installation Type
Configure the SmartEvent and Reporter Suite applications to run on the server.
SmartEvent: A system that reads logs and generates events based on an Event Policy. An IPS event-only
version is also available. SmartReporter is a system that reads logs and generates statistical and data
reports. Choose one or more of these server components:
SmartReporter Server: Contains reports, report definitions and report schedules.
SmartEvent Server: Holds the event (or IPS event) database, event queries, object values and policy
definition.
SmartEvent Correlation Unit: An engine which reads logs and creates events.
For IPS Event Analysis, select both SmartEvent Server and SmartEvent Correlation Unit.
Web/SSH and GUI Clients Configuration
Define the clients that are allowed to connect to Smart-1 appliance using a Web browser, SSH client, or
SmartConsole applications.
Using the First Time Configuration Wizard
Configuring Smart-1