SPECIFICATIONS
iMAG Dimensions
L
iMAG
Meter Size
inch
mm
3"
12.0
305
4"
10.24
260
6"
12.27
312
8"
14.24
362
10"
18.18
462
12"
19.68
500
Flanges
Standard ANSI 150 lb. drilling
5
5
4
4
3
3
2
2
1
1
0
0
0
0
0
FLOW RANGE (3" - 12")
Pipe Size
(Inches in diameter)
Max Flow Rate
(Gallons/Minute)
Cut-off (min) Flow Rate
(Gallons/Minute)
Max Flow Rate
(Liters/Second)
Cut-off (min) Flow Rate
(Liters/Second)
Max Flow Velocity
(Meters/Second)
H
inch
mm
6.80
173
8.12
206
9.22
234
10.22
260
11.22
285
12.28
312
iMAG Accuracy
2
4
10
5
5
10
Flow Velocity
3"
4"
723
1285
3.62
6.43
46
81
0.23
0.41
10
10
T
ID
inch
mm
inch
.68
17.3
2.60
66.04
.62
20.9
3.12
79.25
.69
23.3
5.05 128.27
.69
23.3
6.44 163.58
.69
23.3
8.61 218.69
.81
20.6 10.55 267.97
6
15
20
15
20
6"
8"
2891
5140
14.46
25.70
182
324
0.91
1.62
10
10
Shipping
Weight
mm
pounds
Kg
41
19
35
16
50
23
72
33
128
58
170
78
Cable 1 lb.
8
25
30
25
30
10"
12"
8031
11565
40.15
57.82
507
730
2.54
3.65
10
10
(m/s)
10
(ft/s)
33
33