specification
Nominal supply voltage
12 or 24 V dc
Operating voltage range
10 V to 32 V dc
Fuse / Breakers
Power supply fuse:
• 15 A (SPX-10, SPX-SOL)
• 40 A (SPX-30)
SeaTalk Power out
• 2A at 12 V (fuse protected
at 2A) — SPX-10
• 3A at 12 V (fuse protected
at 3A) — All except SPX-10
SeaTalk
ng
Power out
• 2A at 12 V (fuse protected
at 2A) — SPX-10
• 3A at 12 V (fuse protected
at 3A) — All except SPX-10
Power consumption (standby)
300 mA
SeaTalk
ng
LEN (Load
1
Equivalency Number)
Gyro
Internal GyroPlus fitted as
standard
Environmental conditions
Installation environment
operating temperature
• Operating temperature:
non-operating temperature
-10 ºC to +50 ºC (14 ºF to
relative humidity limit water
122 ºF)
protection
• Storage temperature:
-20 ºC to +65 ºC (-4 ºF to
149 ºF)
• Relative humidity: max
95%
• Drip resistant when
mounted vertically
Technical specification
Dimensions
• Width: 285 mm (11.2 in)
• Height: 212 mm (2.5 in)
• Depth: 65 mm (8.3 in)
Weight
• 1.1 kg (2.42 lbs) — SPX-10
• 2.2 kg (4.85 lbs) — SPX-30
Data Connections
• NMEA 0183: I/O 4800
baud
• SeaTalk
• SeaTalk
Other connections
Fluxgate compass, Rudder
position sensor, Sleep switch,
Power, drive motor, drive
clutch/SOL bypass valve
Fast heading output
• NMEA 0183 — 5 Hz
• SeaTalk
• NMEA 2000 — 10 Hz
Raymarine drive compatibility
SPX-10
X 10 X 30 X SOLENOID
• all Type 1 drives/pumps
(excluding CR pumps).
Drive voltage must match
boat's supply voltage.
SPX-30
• all Type 1, Type 2 and Type
3 drives / pumps. Drive
voltage must match boat's
supply voltage.
SPX-SOL
• CR pumps and solenoid
drive
Drive current output
ng
Drive clutch output X 10 X 30
X SOLENOID
EMC compliance:
ng
— 10 Hz
SPX-10
• Continuous 10A at supply
voltage
• Peak (Limit) 25 A
• Continuous 30A at supply
voltage (SPX-30)
SPX-30
• Continuous 30A at supply
voltage (SPX-30)
• Peak (Limit) 50 A
• 2.0 A at 12 / 24 V selectable
(SPX-10, SPX-SOL)
• 3.0 A at 12 / 24 V selectable
(SPX-30)
• Europe: 2004/108/EC
• Australia and New Zealand:
C-Tick, Compliance Level
2