3.1.1 Power consumption

Supply voltage
48
GSM
48
380
240
48
48
450
GPRS
310
660
420
48
48
530
EDGE
320
670
320
Table 3: Power consumption of GSM/GPRS parts
This confidential document is a property of FALCOM GmbH and may not be copied or circulated without previous permission.
Autobauding (on ASC0 only) detects 1200, 2400,
4800, 9600, 19200, 38400, 57600, 115200, 230400 bps
Supported phonebook types: SM, FD, LD, MC, RC,
ON, ME
Implemented
Programmable via AT command
1 Timeslot
9.05 kbps
13.4 kbps
15.6 kbps
21.4 kbps
Coding schemes and maximum net data rates over air interface
POWER CONSUMPTION
Typ
Unit
GSM/GPRS/EDGE engine
5.0
V
Average supply current
MODE
mA
IDLE mode
DATA mode, PL 5
mA
DATA mode, PL 0
mA
IDLE GPRS
DATA mode GPRS,
mA
(4 Rx, 1 Tx), Tested (Upload 1 x TX)
DATA mode GPRS,
mA
(3 Rx, 2 Tx), Tested (Upload 2 x TX)
IDLE EDGE
DATA mode EDGE,
mA
(4 Rx, 1 Tx), Tested (Upload 1 x TX)
DATA mode EDGE,
mA
(3 Rx, 2 Tx), Tested (Upload 2 x TX)
2 Timeslots
4 Timeslots
18.1 kbps
36.2 kbps
26.8 kbps
53.6 kbps
31.2 kbps
62.4 kbps
42.8 kbps
85.6 kbps
Description
BAND
GSM 900/850
GSM 1800/1900
GSM 900/850
GSM 1800/1900
GSM 900/850
GSM 1800/1900
GSM 900/850
GSM 1800/1900
GSM 900/850
GSM 1800/1900
GSM 900/850
GSM 1800/1900
GSM 900/850
GSM 1800/1900
GSM 900/850
GSM 1800/1900
VERSION 1.01