Technical Specifications - Compac CNG Service Manual

Hide thumbs Also See for CNG:
Table of Contents

Advertisement

Technical Specifications

Operating Conditions:
Compac CNG Dispensers (excluding hose assembly) are designed to operate within the
atmospheric environment. Gas parameters are outlined below.
CNG Dispensers require the following operating conditions:
CNG Dispensers require the following operating conditions:
Maximum water Dew Point
Maximum Working Pressure(Inlet)
General
Specifications
Air temperature range
Air humidity range
Gas type
Gas temperature
Power Requirements
72.
- 25 °C to + 55 °C
10% to 95%
High pressure natural gas
(CNG)
- 40 °C to + 80 °C
(continuous)
- 55 °C to + 80 °C
(intermittent)
- 32 °C at 250bar
275bar (350 bar option)
230V +/-10%, 50Hz, 2A