Troubleshooting - Vogt Hammer VH 10 Manual

Table of Contents

Advertisement

EN

6 Troubleshooting

NOTE
Error
VOGT compressed
air equipment
does not impact or
has no power.
NOTE
Subject to change without notice
32
Please see section 3 and 4.
Possible cause
Piston has started
to rust inside the
casing due to a
lack of oiling.
Dirt has entered
via the air hose.
Too much lubri-
cating oil used
or water in the
rammer.
Excessive contact
forces.
Observe the safety warnings and disposal information from the manufacturer of the
cleaning agent!
Maintenance
• Press the piston back through the tool holder using a
striker.
• Add some VOGT Special Oil or pneumatic oil to the
connection hose and in the tool holder.
• Briefly put the equipment into operation without a tool.
• Interrupt the compressed air supply again.
• Remove the compressed air hose again.
• Repeat the entire procedure a few times.
• Repairs/cleaning must be performed by a specialist
workshop or the manufacturer.
• Observe the warning information below!
• Add a small amount of cleaning agent (e.g. 1 to 2 cm³ of
brake cleaner) into the connection hose.
• Briefly put the equipment into operation without a tool.
• Collect the oil/water/cleaning agent mixture that
comes out.
• Interrupt the compressed air supply again.
• Remove the compressed air hose again.
• Repeat the entire procedure two to three times.
• Add some pneumatic oil into the connection hose.
• Put the equipment into operation.
• Lubricate the chisel holder and reduce the contact force.
Contact:
+49(0)92 78-774 33-0
+49(0)92 78-774 33-11
www.vogt-tec.de

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hammer vh 50Hammer vh 50.18Hammer vh 25Hammer vh 60Vh 30Hammer vh 60.18 ... Show all