Sanification + filtration cartridge

When the exhaust filter led turns on, it is time to replace the filter cartridge:
1.
Turn unit off through main on/off switch (Fig. 11).
2.
Pull unit from cabinet (Fig. 5a) and look for the valve
near the CO2 cylinder.
3.
Close valve (Fig. 14).
4.
Position under the water dispense nozzle a container
and dispense water to empty filter cartridge and tubes.
5.
Remove the filter cartridge form its housing by rotating
counter clock-wise about a quarter turn (Fig. 15). This
will free the filter. Pull downward and remove it.
6.
Fill sanitizing cartridge with 300cc of Neutral
Detergent. Insert the sanitizing cartridge on the filter
head by rotating clock-wise a quarter turn.
7.
Open valve on the base of the unit (Fig. 8).
8.
Dry any water from the base, that could have leaked
during this operation.
9.
Position under the water dispense nozzle a container or
large cup.
10.
Turn main switch. Wait approx.
5 seconds and press "light" button until sanitizing
mode is entered. This will be shown in the display as a
moving red led through all the buttons. During this
operation, the inside of the unit will be sanitized. After
this initial cleaning cycle, the unit will dispense
automatically some cold and ambient water.
11.
Shut off unit from main on/off switch.
12.
Close valve on base of the unit (Fig. 14).
13.
Position under the water dispense nozzle a container
and dispense water to empty sanitize cartridge and
tubes.