Leds
ambient water
ice
blink simultaneously
Leds
ambient water
cold water
carbonated water
blink simultaneously
Leds
carbonated water
ambient water
cold water
ice
blink simultaneously
All leds on
simultaneously
20
Ice forming bin blocked.
Turn unit on/off through main on/off switch on side of unit.
Volumetric turbine malfunctioning. Dispense functions enabled but
during dispense operation the 3 leds will blink.
Main water tank fill time-out. Please check water supply to unit. Make
sure filter shut off valve to be open.
To reset status turn unit on/off through main switch inside cabinet.
All dispense buttons disabled. 2 main causes:
Water present on base of unit. Possible leak.
Water level too high inside water tank. Water discharge blocked.
For the first case switch off and dry the base of the unit.
For the second case turn unit on/off through main switch inside
cabinet.