Spi Parameter Addresses; Devid 20, 21 & 22; Echo - ACS 3200 Series Custom Manual

Pid temperature controllers
Hide thumbs Also See for 3200 Series:
Table of Contents

Advertisement

3200 Series
Parameter
Mnemonic
8 – Target setpoint
9 – No PV
10 – PV is not displayed when controller in Standby
-
Instrument version number. Should be read as a hexadecimal number, for example a value of 0111 hex is instrument V1.11
ADDR
Instrument Comms Address
9.4

SPI Parameter Addresses

This instrument variant supports the following SPI Device types (no configuration is required, the devices
automatically respond to requests made to these device types).
Mold Temperature Controller (DEVID 20)
Chiller (DEVID 21)
Dryer (DEVID 22)
Self Tuning General Purpose Temperature Controller (DEVID 26)
General Purpose Temperature Controls (DEVID 27)
NB: The SPI variant of the 3200 controller supports only Fahrenheit units.
The SPI device address is set in the range 32..255 (hexadecimal 20 to FF) using the 'Addr' parameter in the Level 2
scroll list, or in the Level 3 'Comms' List.
9.5
DEVID 20, 21 & 22
Mold Temperature Controllers, Chillers, and Dryer DEVIDs support the following set of parameters.
9.5.1

ECHO

20 20
POLL:
20 21
SELECT:
Open – 4 Bytes
FORMAT:
ASCII
UNITS:
Controller integrity command. Controller will accept and retain the data provided. The controller will provide
DESCRIPTION:
the retained data in response to a poll enquiry.
VERSION
20 22
POLL:
N/A
SELECT:
Open 4 bytes ASCII
FORMAT:
ASCII
UNITS:
SPI version command. The controller will provide a fixed SPI version number (0400 for 3200).
DESCRIPTION:
ACS 3216 Operators Manual
Parameter Name
Modbus Address
107
131
25