To Select Access Level 3 Or Configuration Level - ACS 3200 Series Custom Manual

Pid temperature controllers
Hide thumbs Also See for 3200 Series:
Table of Contents

Advertisement

6.1.4

To Select Access Level 3 or Configuration Level

Do This
1.
From any display press and hold
for more than 5 seconds
2.
Press
or
the passcode for Level 3
When the LEV3 GOTO view is
3.
shown, as in paragraph 1 above, press
to select 'Conf'
4.
Press
or
to enter the
passcode for Configuration level
5.
Press and hold
for more than 3
seconds
6.
Press
to select the required level
eg LEV 1
A special case exists if a security code has been
configured as '0' If this has been done it is not necessary to
enter a code and the controller will enter the chosen level
immediately.
When the controller is in configuration level the
ACCESS list header can be selected from any view by
holding down the
button for more than 3 seconds.
Then press
again to select 'ACCES'
10
The Display You Should See
To Select Level 3
Lev 3
go to
CODE
to enter
To Select Configuration level
Conf
go to
111
code
Conf
To Return to a Lower Level
Conf
go to
Lev1
Additional Notes
The display will pass from the current operating level, for
example, Lev 1 to Lev 3 as the button is held down.
(If no button is then pressed for about 50 seconds the display
returns to the HOME display)
0
C ODE
The Level 3 code is 11:
11
If an incorrect code is entered the display reverts to 'g o t o '.
The controller is now in the level 3 will then revert to the HOME
display
Note:
must be pressed quickly (within 2 seconds) before
the controller requests the code for level 3
0
(If no button is then pressed for about 50 seconds the display
C ODE
returns to the HOME display)
The configuration code is 111:
If an incorrect code is entered the display reverts to 'g o t o '.
The controller is now in Configuration level will now show
Conf
The choices are:
LEV 1
Level 1
LEV 2
Level 2
LEV 3
Level 3
C o n F
Configuration
It is not necessary to enter a code when going from a higher level
go to
to a lower level.
Alternatively, press
then press
The display will then flash 'ConF' for a few seconds and the
controller will then go through its start up sequence, starting in
the level selected.
Do not power down while Conf is flashing. If a power down
does occur an error message will appear.
3200 Series
and scroll to the A c c e s list header,
to select the required level.
ACS 3216 Operators Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

3216

Table of Contents