TTR Manual
Communications system
www.safeline-group.com
11.2019
TTR v.2.04 EN
An innovation manufactured in Tyresö, Sweden
© 2019 SafeLine and all the SafeLine products and
accessories are copyrighted by law.

Advertisement

Table of Contents
loading

Summary of Contents for Safeline TTR

  • Page 1 TTR Manual Communications system An innovation manufactured in Tyresö, Sweden www.safeline-group.com © 2019 SafeLine and all the SafeLine products and 11.2019 TTR v.2.04 EN accessories are copyrighted by law.
  • Page 2: Table Of Contents

    Wiring diagram,Emergency light and pictograms Wiring diagram,Extra station card Wiring diagram PSTN Line Activating the SIM card Start up LED indication SafeLine TTR Front panel LED indication pictograms Test procedure after installation Configuration Configuration methods Remote Config. with telephone first step Remote Config.
  • Page 3: Introduction

    - This quality product is dedicated for the lift industry. It has been designed and manufactured to be used for its specifi ed purpose only. If it is to be used for any other purpose, SafeLine must be contacted in advance.
  • Page 4: Ttr Alarms

    TTR board (not autodetect). • Install jumpers on the TTR board, so they stand as the unit which is replaced (same jumper names). • Remember to attach the unit, and tighten the screws in the lid to avoid the device to “rattle”.
  • Page 5: Component List

    Component list Introduction TTR v.2.04 EN...
  • Page 6 6. Jumpers for emergency button Selects NO/NC for the emergency button 7. Jumpers for pictogram, emergency light and sounder The outputs from the SafeLine TTR can be configured by use of the jumpers J8 and J9 to activate pictograms emergency light and sounder switch.
  • Page 7 1. Terminal or RJ12 connector for PSTN line. Internal connection of PSTN line. 2. GSM antenna connection, SMA 3. SIM-card holder 4. Volume controls For the extra remotes. Turn right to increase the volume. 5. Terminals For the extra remotes. 6. GSM antenna Introduction TTR v.2.04 EN...
  • Page 8: Installation

    To avoid GSM interference: Place the main unit, the stations and the GSM antenna more than 1.5 meters apart. SafeLine SL6+ >>1.5 m >>1.5 m 0,1m ² >>1.5 Mounting interface boards GSM card PSTN card Extra station card Installation TTR v.2.04 EN...
  • Page 9: Wiring Diagram,Emergency Bell And Light

    Emg. light - Jumper settings With the jumpers “J8” and J9 in the position as shown left, the SafeLine TTR can supply backup power for emergency light in the lift car. The jumpers “J1”, “J2” and “J5” shall be set as shown left and shall not be changed.
  • Page 10: Wiring Diagram,Emergency Bell And Pictograms

    Green pict. Jumper settings With the jumpers “J8” and J9 in the position as shown left, the SafeLine TTR can operate pictograms according to EN 81-28 / EN 81-70. The jumpers “J1”, “J2” and “J5” shall be set as shown left and shall not be changed.
  • Page 11: Wiring Diagram,Emergency Light And Pictograms

    Emg. light - Jumper settings With the jumpers “J8” and J9 in the position as shown left, the SafeLine TTR can sypply backup power for emergency light in the lift car. The SafeLine TTR can also operate pictograms according to EN 81- 28 / EN 81-70.
  • Page 12: Wiring Diagram,Extra Station Card

    3. Make a call from your phone to verify that the SIM card is active, before you move it to the SafeLine TTR. 4. Also make a call to SafeLine TTR after insertion to check that it is possible to get a proper connection.
  • Page 13: Start Up

    Continuous green Call connected. Reset button Hold for 4 sec - Show GSM signal strenght. Press 3 times - Start a battery condition test Press once - Resets an active alarm. Aborts calls in progress. Start up TTR v.2.04 EN...
  • Page 14 The Green pictogram LED The Yellow Pictogram LED, is turns on as soon as the lit as soon as the alarm button SafeLine unit detects a is pressed longer than the set responding voice. The LED delay. is turned off when the call is terminated.
  • Page 15: Test Procedure After Installation

    Connect 12V battery plug LED 1 All LEDs are off flashes red Check battery voltage SafeLine will make a self test LED 3 flashes LED 3 flashes red 5 times. green 5 times. Long tone in the speaker. Short tone in the speaker.
  • Page 16: Configuration Methods

    To configure the unit through the SafeLine CONNECT app, the CONNECTable (*CONNECTABLE) is required. Plug in CONNECT- able through the unit’s serial port and configure the unit through the app just like any other unit. The TTR is presented as “SL3000” in CONNECT. CONNECTable Configuration TTR v.2.04 EN...
  • Page 17: Remote Config. With Telephone First Step

    Remote Config. In order to remotely configure the SafeLine, the unit must first be put into configuration mode via voice communication mode. To with telephone enter voice communication mode, refer to the instructions below. first step After the unit has been set in voice communication mode, follow the steps for remote configuration on the next page.
  • Page 18: Remote Config. With Telephone Second Step

    Enter setting, eg: *11* 012341234 # End parameter: *11* 012341234 # Call disconnected or end of configuration. 2 short beeps? SafeLine will restart with new settings Invalid input (one long tone) Last code has to be reentered Configuration TTR v.2.04 EN...
  • Page 19: On-Site Configuration With Telephone

    Enter setting, eg: *11* 012341234 # End parameter: *11* 012341234 # Call disconnected or end of configuration. 2 short beeps? SafeLine will restart with the new settings Invalid input (one long tone) Last code has to be reentered Configuration TTR v.2.04 EN...
  • Page 20: Configuration Example

    Refer to the “Configuration methodes” chapter before reading this example, to know how to get started. example The example will assign the following settings to the SafeLine SL6: • ID code for P100 protocol to 12345677. • First phone number to emergency call centre to 42345688.
  • Page 21: Configuration Codes Table

    00-99 days. Always two digits. Max 3 days according to EN 81-28. 00 = No test alarms Test alarm protocol *31* Protocol test alarm 0 = P100 3 = CPC 4 = Phone number used as ID. Configuration TTR v.2.04 EN...
  • Page 22 1 = Enables recorded message. *63* Play the the recorded message. Options for the recorded *64* 0 = Disable recorded message. message from lift pit 1 = Enables recorded message. *64* Play the the recorded message. Configuration TTR v.2.04 EN...
  • Page 23 Detect dial tone *83* 0 = Off 1 = On (Default) Set to off if SafeLine has problem to detect the dial tone. Receipt to alarm receiver *84* Select which message(s) to send to the alarm receiver at an alarm call.
  • Page 24 *21*0#, *22*0#, * 27*03#, *80*1#, *84*1#, *88*1# 3 = Default CPC(The following codes will be set): *21*3#, *22*3#, *27*03#, *80*1#, *84*1#, *88*1# 4 = Default VOICE(The following codes will be set): *21*1#, *22*1#, * 27*03#, *80*1#, *84*1#, *88*1# Configuration TTR v.2.04 EN...
  • Page 25 ”4”. The call is terminated by pressing ”#”. It is possible to enter manual voice switching mode although the unit is programmed as automatic by pressing ”*”. No ascending tones will be heard. Configuration TTR v.2.04 EN...
  • Page 26: Operating

    Calling with The TTR can call in the following ways: SafeLine TTR Intercom between machine room and car/pit/car-top, see below. Make calls with a normal fixed phone line and through GSM. Emergency calls to numbers at the press of the alarm button.
  • Page 27: Intercom Between Machine Room & Car/Pit/Top Of Car

    4 5 6 7 8 9 4 5 6 4 5 6 7 8 9 7 8 9 Press 00 to enter programming mode. 4 5 6 7 8 9 4 5 6 7 8 9 Operating TTR v.2.04 EN...
  • Page 28: Emergency Calling Process

    Emergency alarm activated Wait 1 minute Receiving Line missing or busy tone Calling 1st phone number Answer? Calling 2nd phone number Answer? Calling 3rd phone number Answer? Calling 4th phone number Answer? Alarm operator made connection Operating TTR v.2.04 EN...
  • Page 29: Service

    Testing the battery alarm: • Unplug the battery contact during the battery status check. • The SafeLine TTR will now emit a battery alarm and LED 2 and the battery alarm relay will be activated (if so configured). Cancelling the battery test: •...
  • Page 30: Troubleshooting

    The unit can not make an alarm call. At least one phone number (and one ID code if using data identification) must be programmed to enable making a call from the unit. Refer to the parameter list (*11*). Service TTR v.2.04 EN...
  • Page 31 3.2: Effective use of spectrum allocated Firmware used during assessment GL865-Dual V3: 16.00.152 / 16.01.150 / 16.01.153 SafeLine SL3000 2.20 Tyresö, 2017-04-07 Lars Gustafsson, Technical Manager, R&D , SafeLine Group Antennvägen 10, 13548 Tyresö, Sweden +46 (0)8-447 79 32, www.safeline-group.com...
  • Page 32 Support: +32 (0)4 85 89 08 95 SafeLine Deutschland GmbH Kurzgewannstraße 3 · D-68526 Ladenburg · Germany Tel.: +49 (0) 6203 840 60 03 · sld@safeline.eu SafeLine Group UK Unit 47 · Acorn Industrial Park · Crayford · Kent · DA1 4AL · United Kingdom Tel.: +44 (0) 1322 52 13 96 ·...