DSP-4000 Series
Getting Started Guide
Permanent Link Interface Adapters
(DSP-4000PL/4300)
Caution
To avoid damaging the adapter and to ensure
maximum accuracy of test results, never
pinch, kink, or crush the adapter's cable.
Never use the cable as a handle to pick up
the DSP test tool. Follow the handling
guidelines given in Figures 3 and 4.
For the best accuracy, keep the adapter's
cable as straight as possible during testing.
To avoid latent or immediate damage due to
electrostatic discharge:
Before handling a module or an adapter with
no module attached, ground yourself when
possible by touching a grounded, conductive
surface.
Always remove the adapter from the DSP test
tool before changing the personality module.
Always keep a personality module attached
to the adapter cable.
12
Tighten the screw snugly with your fingers
only. Do not overtighten. Doing so can
damage the module or the end of the cable.
Always store the personality module in its
original, static protection bag when not in
use.
˚
360
twist maximum
Figure 3. Permanent Link Adapter Handling
Guidelines
4" (10 cm)
minimum bend
Storage
ank85f.eps