Operating Conditions: Process; Medium Temperature Range; Pressure Loss; Medium Pressure Range (Nominal Pressure) - Endress+Hauser Proline t-mass 65F Technical Information

Thermal mass flow measuring system. direct mass flow measurement of gases
Hide thumbs Also See for Proline t-mass 65F:
Table of Contents

Advertisement

Proline t-mass 65F, 65I

Medium temperature range

Pressure loss

Medium pressure range (nom-
inal pressure)

Medium pressure

Endress+Hauser

Operating conditions: Process

Sensor
t-mass F:
–40 to +100°C (–40 to 212°F)
t-mass I:
–40 to +130°C (–40 to 266°F)
Seals:
t-mass F:
Viton –20°C to +100°C (–4°F to +212°F)
Kalrez –20°C to +100°C (–4°F to +212°F)
EPDM –40°C to +100°C (–40°F to +212°F)
t-mass I:
Nitrile –35°C to +130°C (–3°F to +266°F)
Kalrez –20°C to +130°C (–4°F to +266°F)
EPDM –40°C to +130°C (–40°F to +266°F)
2 mbar (0.029 psi) maximum (without flow conditioner)
t-mass F:
–0.5 to 40 bar gauge (–7.25 to 580 psig)
t-mass I:
–0.5 to 20 bar gauge (–7.25 to 290 psig)
Pressure temperature curve to EN (DIN), stainless steel
bar
PN 16/40
45
40
PN 40
35
30
25
20
PN 16
15
10
5
0
-200 -100
0
100
200
300
Pressure temperature curve to JIS B2238 and ANSI 16.5, stainless steel
10/40 K
bar
45
40
35
30
25
20
20 K
15
10
10 K
5
0
-200 -100
0
100
200
300
°C
400
Class 150/300
psi
1600
1400
1200
1000
800
600
Cl. 300
400
Cl. 150
200
0
°C
400
-300 -100
0 100
°F
300
500
700
a0005240
a0005241
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Proline t-mass 65i

Table of Contents