2.2.7 Mounting of Line/Trunk Card on 1000 IVS PIM

Mount the Line/Trunk cards in the following slots on the Remote PIM. Connect the line cables referring to
3-24
through
Figure 3-26
Remote PIM
LINE/TRUNK
CARD
*1 When providing DAIB card only (Max. 23 ports): LT01~LT03slot
*2 When providing one DAIB card and one DAIC card (Max. 4 ports): LT00~LT08 slot (Mounted DAIB in MP, mountedDAIC in LT07 so LT
08 is available for 8 ports card)
*3 When DAIC is mounted in slot 07, slot 06 must use the 4-port Line/Trunk card, so that the last 4 ports of slot 06 do not interfere with the
DAIC card and when DK00 can assign on this last 4-ports, the system can have a Max. of 44 ports.
The CSI card can not be used on the Remote PIM.
Note 1:
Note 2:
One port of the last 24 ports can not be used for line/trunk, because it is used for control
signaling channel.
REMOTE PIM TYPE
1000 IVS
(48 Port PIM)
CHAPTER 3
Page 48
Revision 2.0
and
Table
3-9.
LTC0
Figure 3-24

Mounting Location of Line/Trunk Card (1000 IVS)

Table 3-9 LTC Connector Accommodation (1000 IVS)
LTC CONNECTOR
*1
*2
LTC1
BWB
FRONT
LTC0
LTC1
ND-46550 (E)
P
W
R
CARD SLOT NUMBER
LT01~LT03
LT04~LT08, LT00
Figure