NEC NEAX2000 IVS User Manual page 28

Remote pim system
Table of Contents

Advertisement

(3)
Switch Settings
In
Table
3-2, the figure in the SWITCH NAME column and the position in
TION column indicate the standard setting of the switch. When the switch is not set as shown by the figure
and
, the setting of the switch varies with the system concerned.
SWITCH
SWITCH
NAME
NUMBER
SW1 (Rotary
SW)
1
3 2
Note 1
Note 2
MB (Toggle SW)
ON
Note 3
SW1 (Piano Key
SW)
OFF
4
3
2
1
ON
CHAPTER 3
Page 20
Revision 2.0
Table 3-2 Switch Settings on PN-DAIA Card
SETTING
POSITION
0 – F
FP (Firmware Processor) Number setting for DAIA card.
By this setting, system regards DAIA card and the opposite DAIB
card as one firmware processor.
0
Not used
1
FP No. 1
2
FP No. 2
3
FP No. 3
4 – F
Not used
UP
For make-busy
For normal operation
OFF
ON
For supplying 1.5 MHz clock to PLO 0
1
No clock supply to PLO 0
OFF
Note 4
ON
For supplying 1.5 MHz clock to PLO 1
2
No clock supply to PLO 1
OFF
Note 4
Always set to OFF
OFF
3
Always set to OFF
OFF
4
FUNCTION
ND-46550 (E)
in the SETTING POSI-
CHECK

Advertisement