Pve, Electrical Actuation; Pvpe, Electrical Relief Valve, Normally Open - Danfoss PVG 120 Technical Information

Proportional valve group
Hide thumbs Also See for PVG 120:
Table of Contents

Advertisement

Technical Information
Technical Data

PVE, electrical actuation

PVPE, electrical relief valve, normally open

16
PVG 120 Proportional Valve Group
PVH, Hydraulic Actuation (continued)
PVH data
Maximum pressure on port T
(It is recommended that the tank connection from the hydraulic remote control unit
PVRH is taken directly to tank.)
PVE, electrical actuation
PVE actuation
Hysteresis (applies to the electrical
1)
actuation only)
Reaction time from neutral position to max.
spool travel
Reaction time from max. spool travel to
2)
neutral position
Pilot oil flow pr. PVE
Neutral position without voltage
Locked with voltage
Enclosure to IEC 529
1)
The hysteresis is stated at rated and f = 0,02 Hz for a cycle. One cycle includes the movement from
neutral position to max. spool travel direction A, via neutral position to max. spool travel in direction B,
and back to neutral position. Further information can be obtained by contacting the Danfoss Power
Solutions Sales Organization.
2)
Reaction times for PVEH is reduced by 20 by 30 ms if the voltage is not interrupted during the neutral
positioning (remote control lever without neutral position switch).
3)
Total oil consumtion for a spool movement from N to full A or B: 0.0035 l [0.0009 US gal].
PVPE, electrical relief valve, normally open
Maximum operation pressure
Maximum pressure drop at flow of 0.2 l/min [0.053 US gal/min]
Oil temperature (inlet
temperature)
Maximum coil surface temperature
Ambient temperature
Oil viscosity
Response time for pressure relief to tank
Enclosure to IEC 529
Rated voltage
520L0356 • Rev JA • Mar 2014
PVEO ON/OFF
Typical
-
Typical
250 ms
Maximum
350 ms
Typical
240 ms
Maximum
330 ms
0 l/min / [0 US gal/min]
3)
0 l/min / [0 US gal/min]
IP65
Recommended temperature
Min. temperature
Max. temperature
Operating range
Min. viscosity
Max. viscosity
Pressure, bar [psi]
3 [45 ]
PVEH Proportional
High
4%
250 ms
280 ms
150 ms
200 ms
350 bar [5085 psi]
1.2 bar [17 psi]
30 to 60 °C [86 to 140 °F]
–30 °C [–22 °F]
90 °C [194 °F]
155 °C [311 °F]
–30 to +60 °C [–22 to +140 °F]
2
12 to 75 mm
/s [65 to 347 SUS]
2
4 mm
/s [39 SUS]
2
460 mm
/s [2128 SUS]
600 ms
IP 65
12 V
24 V

Advertisement

Table of Contents
loading

Table of Contents