The main features of PVEH:
Inductive transducer
Integrated pulse width modulation
Low hysteresis
Fast reaction time
Hirschmann or AMP connector
Fault monitoring with transistor output for signal source
Low electrical power
No set-up procedure
PVEH parameters
Supply voltage U
DC
Current consumption at rated voltage
Signal voltage
Signal current at rated voltage
Input impedance in relation to 0.5 • U
Input capacitor
Power consumption
PVEH
Maximum load
Reaction
time at fault
520L0356 • Rev JA • Mar 2014
A
B
T
T
P
P
Rated and Range
Maximum ripple
Neutral
A-port ↔ B-port
DC
Active / Passive
C
V310099.A
11 V to 32 V
5%
0.57 (0.33) A @ 12 V
0.3 (0.17) A @ 24 V
0.5 x U
DC
0.25 • U
to 0.75 • U
DC
DC
0.25 mA to 0.70 mA
12 KΩ
100 ηF
7 (3.5) W
100 mA
60 mA
500 ms