Reader Installation

The following parts are provided with the Reader:
Part
V740 RFID Reader
Power Supply
Operation Manual
IMPORTANT: Be sure the user reads the section
on Declarations to maintain compliance with FCC
regulations.

Install the Reader

You can place the Reader on a shelf or mount it to
a wall.
To mount the Reader on a wall:
1. Hold the Reader in its mounting location and
mark the position of the mounting screws (2).
Minimum screw size is #12 (M5).
MODULE A
MODULE B
FAULT / ERROR
Mounting
holes
2. Drill holes for the screws and install wall
anchors if required.
3. Insert the screws and tighten until almost flush
with the wall.
4. Slip the Reader over the screws and slide
down to lock the screws in the keyhole
openings.
5. Tighten the screws.
Mechanical Loading - Mounting of the equipment
in the rack should be such that a hazardous
condition is not achieved due to uneven
mechanical loading.
V740 RFID READER
OPERATION MANUAL
Qty.
Part Number
1
V740-BA50C**-US
1
-
1
This manual
STATUS
ACTIVITY
NOTE. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.

Install the Antennas

The antennas can be mounted directly to a variety
of surfaces. Follow the installation instructions
provided with the antennas.

Connect the Reader

A = RJ-45 Ethernet port
B = Safe Mode button
One to four dual-antennas can be connected to the
Reader, depending on the number of cards
installed. Silk-screen markings on the Reader
identify the cards installed.
1. Connect required UHF antennas to the ports
on the Reader (see "Antenna Connection
Option" on page 6).
IMPORTANT: Connect antennas to the ports
before applying power to the Reader. Any port
not having an antenna connected to it will be
disabled when the Reader is powered on.
2. Verify that all antennas are securely
connected.
3. Connect the Reader to the network by plugging
an Ethernet cable into the Ethernet port.
or
Connect the Reader to a PC (personal
computer) by plugging a crossover Ethernet
cable into the Ethernet port.
[If DHCP is to be used, then the network must
be connected before powering up the Reader.
If a DHCP server is not found the Reader will
fall back to the IP address: "10.0.0.101".]
IMPORTANT: The Reader and the antennas
are installed by only professionals at
specific location and also they must be
used at the separate distance of at least 21
cm (8.3in).
5 of 27
C = RS232/RS485,GPIO(not
available)
D = DC power input
REV. 1.1