6. ELECTRICAL CONNECTIONS

To prevent possible severe electrical shock to individuals or extensive damage to the unit, the icemaker must be connected
via the flexible supply cord supplied with the icemaker to an appropriate outlet socket installed in accordance with local codes
and regulations i.e. AS / NZS 3000.
Disconnect the main power supply before any maintenance, repairs or cleaning is undertaken.
* It is recommended that these appliances are connected to a separate 240VAC supply, protected by an appropriate circuit
breaker and Residual Current Device. Check the nameplate on the icemaker for the supply requirements.
* The main control box fuse is rated at 5A and should only be replaced by a qualified service engineer.
* The service of a licensed electrician may be required to ensure the installation is in accordance with the local codes and
regulations.
* [IM-240NE]
In accordance with the requirement of the IEC standard, the maximum permissible system impedance (Zmax) at the interface
point of the power supply to be connected with this icemaker must be 0.23+j0.23 ohm. Determine in consultation with the
supply authority, if necessary, that the icemaker is connected only to a supply of 0.23+j0.23 ohm or less.
* The wires in the mains lead are coloured in accordance with the following code:
Green & Yellow = Earth
Blue = Neutral
Brown = Live

7. WATER SUPPLY AND DRAIN CONNECTIONS

* The service of a licensed plumber may be required to ensure the installation is in accordance with the local codes and
regulations.
[Connection to the water supply]
* The connections to the mains water supply must be made in accordance with the Plumbing Code of Australia and in
accordance with AS / NZS 3500.1 and AS / NZS 3500.2. This appliance incorporates backflow protection complying with AS /
NZS 3500.1. No further backflow protection is required for connection to the water supply.
* Icemaking water must be potable water. Where
scaling can be caused by water quality:
- Installation of an external filter or softener is
recommended. Contact your local water treatment
professional or Hoshizaki service agent.
- C h a n g e t o t h e " f u l l d r a i n f l u s h " m o d e i s
recommended. Contact your local Hoshizaki
service agent.
* Water supply pressure should be minimum 0.07
MPa (0.7 bar) and maximum 0.78 MPa (8 bar).
If the pressure exceeds 0.78 MPa (8 bar), use a
proper pressure reducing valve. Do NOT throttle
back the supply tap.
* Attach the angle end of the inlet hose to the G3/4"
water inlet fitting on the rear of the icemaker.
* Be sure to use the new inlet hose-sets supplied
with the appliance. Do not reuse any other inlet
hose-set.
* Ensure rubber tap washers are correctly positioned.
Hand tighten the inlet hose sufficiently to provide a
leak free joint.
WARNING
THIS APPLIANCE MUST BE EARTHED
WARNING
Connect to potable cold water supply only.
Air-Cooled Model
Inlet Hose
Outlet Hose
6
Potable Water
Inlet G3/4
Drain Outlet R3/4
IM-100CNE
Water Supply Tap
Inlet Hose
Drain Outlet Rc3/4
3/4-3/4 Nipple
Outlet Hose