Laerdal SimBaby should be operated by trained persons. Treat instructions, it may cause harmful interference to radio SimBaby as you would treat a real patient. A general inspection communications. In that case the user is encouraged to attempt should be conducted regularly. Do not use the product if cables or correction of the interference by: tubings have signs of damage.
SimBaby is a full body, 6 months old infant manikin that allows the simulation of a wide range of skills and assessment to develop both individual and team skills.
Items included Getting started (See also Presentation CD-ROM included with the SimBaby or The Laerdal SimBaby includes the following main components: www.laerdal.com for details regarding connections) Laerdal SimBaby Manikin SimBaby Software CD-ROM Link Box Presentation CD-ROM: Set-up/Features/Configurations The Link Box connects the manikin to the computer.
Page 5
Option 2: Regulator Unit Air and CO Source (optional) If you have purchased Laerdal SimBaby with the Regulator Unit, attach one end of the double lumen hose to the “Air/CO , out to Option 1: Compressor Unit Manikin”...
Page 6
5. Touch the green check mark after all targets have been touched. USB Camera The USB Camera provides enhanced debriefing possibilities. Video input is synchronized with the SimBaby scenario log. To set-up the camera, see Install Guide and Directions for Use included in your camera packaging.
Patient Monitor display and lung sounds - The tidal volumes dynamically alter in line with the selected respiratory rate c) SimBaby accepts a wide range of airway management devices and techniques. Some examples are: - Bag-Valve-Mask (BVM) - Oral/nasal pharyngeal airways - Endotracheal tubes - nasal and oral [recommended ET tube size is 3.5.
Page 8
Close drain plug Pulses when fluid is running freely. Using a 22 gauge (or smaller) needle for a) SimBaby has palpable pulses: IV training increases the life of the IV leg skin and vein. For IO Bilateral femoral pulse training a 14 gauge (or smaller) needle is recommended.
Page 9
Starting the software and triggered by pre-defined events. These events may be either The SimBaby SW is started by clicking the SimBaby icon on the automatically registered events such as “time” or a defibrillator computer desktop. After entry of password (optional) and shock, or by manually entered events such as administration of selecting a profile, the SimBaby starts up in the default mode...
Page 10
If you paused a running scenario, click on the play To select the desired monitor configuration: ( ) button from the main SimBaby GUI to resume the simulation. 1. Click “view” For more information on the Debrief viewer, refer to the help files.
After use - Be sure that compressed air is not present in the manikin when training session is over. - Clean manikin skin with mild soap and water. Make sure that no water comes inside the manikin. Do not submerge manikin. - Clothes can be hand or machine washed with soap or laundry detergent in warm water, max.
Page 12
Esophagus filter assy IV Arm After each session/course the esophagus filter assy shall be replaced When excessive leaking occurs at the puncture sites, a new vein and by a new one. skin should be installed to reduce loss of fluid. 1) Remove chest skin (see procedure above).