Selecting I/O Popup Menu
and Parameters
Assigning Output Line Functions
(continued)
(continued)
Your Action
Comments
Note that the Not Used box in the Output Line Function
menu has a shaded square (0) This indicates that Not Used
the currently assigned function for output line #l.
Pick a function for output
line #l, if appropriate.
Refer to your Output Line Planning Sheet from Appendix
A, and pick the appropriate function box in the Output Line
Function menu for output line #l.
Note that if you pick a different function than the current
one, the new function will be highlighted
in the Output Line
Function menu and will also appear in the Output
Assignment menu.
Pick the functions for the
remaining output lines.
Refer to your Output Line Planning Sheet and assign the
appropriate functions to the remaining output lines.
NOTE:
Be certain to assign "Not Used" to all output lines
that are not to be used in your application. This ensures that
no signals will be present on the unused lines.
Look at the two "Duration"
boxes in the Output
The two boxes display the currently selected pulse duration
Assignment menu.
for the Results, Data Valid, and Master Range signals
for the two tool sets.
The pulse duration is stated in milliseconds,
and the
acceptable range is 1 to 2000 milliseconds.
NOTE:
If you specify 0 (zero) milliseconds,
the signals will
be latched. They will be updated at the completion of the
next inspection cycle.