2. Set the sub module address according to the DIP rules, and install the rubber cover
back.
Digit 1, 2, 3, 4 are used to coding the sub module address; Digit 5, 6, 7, 8 are reserved.
Valid sub module address range is 1 to 8. The No. should be unique for sub modules
that connected to the same main unit.
The sub module address and corresponding switch status as below.
Sub Module
Address
Digit 1
Digit 2
Digit 3
Digit 4
4.2 One-Module Installation
4.2.1 Installation Accessory Description
Video Intercom Module Door Station·User Manual
1
2
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
Figure 4-2 Front and Side View
3
4
.5
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
OFF
OFF
6
7
8
OFF
ON
OFF
ON
ON
OFF
ON
ON
OFF
OFF
OFF
ON