3. Ice Purge Cycle Bypass

To speed up the diagnostic process, the 5-min. ice purge cycle may be bypassed
by pressing the "SERVICE" button on the control board after the gear motor starts.
WARNING! Risk of electric shock. Care should be taken not to touch live terminals.
B. Controls and Adjustments
Dip switches are factory set. Failure to maintain factory settings may adversely
affect performance and warranty coverage. For more information, contact your
Hoshizaki Certified Service Representative.

1. Default Dip Switch Settings

The S1 dip switch settings are factory-set to the following positions:
Dip Switch No.
F-330BAJ
F-330BAJ-C
Auxiliary Code: E-0
Auxiliary Code: F-0 and Later
NOTICE
1
2
3
4
OFF OFF OFF OFF OFF OFF OFF
OFF OFF OFF OFF OFF OFF OFF
Normally off (factory use)
Bin Control (BC) (mechanical stand-alone) Shutdown Delay
Bin Control Selector
Continuous Dispensing Timer
(DCM models only, do not adjust on modular icemakers)
Drain Frequency Control
Bin Control 1 (infrared sensor) Shutdown Delay
Normally off (factory use)
Mechanical Shutdown Delay
Periodic Agitation (DCM-270 only) and Ice Purge Timer
Bin Control Selector
Continuous Dispensing Timer
(DCM models only, do not adjust on modular icemakers)
Drain Frequency Control
infrared sensor Shutdown Delay
31
5
6
7
8
ON
ON
9
10
OFF OFF
OFF OFF