The following parameters are for values that are based on a stand-alone controller
being used for a high temp application (dairy produce, fresh meat, chilled drinks
etc.), with electric defrost.
DESCRIPTION
Main setpoint
Differential (hysterises)
Lower limit of main setpoint
Upper limit of main setpoint
Minimum time interval between successive
switching of the compressor
Max. temperature alarm differential
Maximum or minimum temp. alarm delay
Time interval between defrost cycles
Max Defrost Cycle time
Target defrost remperature
Time period for supplimentary defrost
Defrost Recovery time
Compressor function during defrosting
Drain Down
Fan operation mode during normal controller
function
Fan activation delay at controller startup and
after defrosting
Fan activation temperature at controller startup
and after defrosting
Display Offset
2k NTC and PT1000 probe selection
Unit of temperature measurement
Compressor function during a probe failure
Compressor ON time during probe failure
Compressor OFF time during probe failure
Local control or remote access control via
®
Genus
network
Stub number when connected to Genus
network
Case number when connected to Genus
network
®
Connect to Genus
Network
Defrost cycle 1 time
Defrost cycle 2 time
Defrost cycle 3 time
Defrost cycle 4 time
First defrost cycle after controller startup
Minimum temperature alarm differential
11.1. Appendix A – Default Factory Setting Parameters
LIMIT / OPTIONS
(d3 ... d4)
o
0...+ 20
C
o
-60...(d4)
C
o
-76...(d4)
F
o
(d3)...+ 200
C
o
(d3) ... + 392
0...999 s
o
0...+50
C
0...99 min.
1...999 h.
1...999 min.
o
-60...+ 100
C
o
-76...+212
F
0...99 min
0...99 min.
0 = always OFF
1 = always ON
0...99 min.
0 = linked to the compressor
operating mode
1 = always ON
0...99 min.
o
-60...+ 100
C
o
-76...+212
F
o
-20...+20
C
0= PT1000
1= 2k NTC
o
0 =
Celsius
o
1=
Fahrenheit
0 = always OFF
1 = always ON
2 = timed ON & OFF
0...99 min.
(do not set to "0")
0...99 min.
(do not set to "0")
0 = Local, 1= Remote
®
0...99
®
0...9...A...U
0 = Off, 1 = on
00:00...23:50 hrs (00...235)
00:00...23:50 hrs (00...235)
00:00...23:50 hrs (00...235)
00:00...23:50 hrs (00...235)
0= after 10 minutes
1= after d8 (hours)
o
0... +50
C (32...+122
Table 5. Default Parameter Configuration
20
11.

APPENDIX

DEFAULT VALUE
o
o
0
C (+32
F)
o
o
+1
C (+34
F)
o
o
-50
C (-58
o
+90
C (+194
F
120 s.
o
o
+5
C (+41
F)
20 min.
4 h.
30 min.
o
+10
C (+50
0 min.
30 min.
0
2 min.
1
5 min.
o
o
+5
C (+41
F)
o
o
0
C (+32
F)
1
0
2
3 min.
5 min.
0
0
0
0
010
070
130
190
1
o
o
o
F)
+2
C (+35
F)
F)
o
F)
o
F)