Operation
1. When triggered (angle of tilt sensor deviates from resting position) the sensor will send a Z-Wave
message of type "basic set 0xFF". When the tilt sensor is restored to a closed position, a Z-Wave
message of type "basic set 0x00" is transmitted.
2. The sensor unit is programmed with two Association groups. Group 1 can store the node ID of up to
five controllers. Controllers will all receive a "basic set 0xFF" when triggered and "basic set
0x00" once the sensor is restored to normal position. Group 2 stores the node IDs for up to five
devices that can be activated with a basic set of 0xFF when the sensor is triggered. Such devices
include chimes, sirens, or light switches. Each device in group 2 listens for Z-Wave messages of type
"basic set 0xFF".
3. Exclusion is the process of removing a sensor from a Z-Wave network. To exclude the tilt sensor from
a Z-Wave network, place the controller into "exclusion mode" (see controller manufacturer's
instructions to put the controller into exclusion mode). Once the controller is in exclusion mode,
remove the battery from the tilt sensor. Wait ten seconds and then replace the battery. When the
battery is replaced, check to see if exclusion mode was successful by observing the LED. If exclusion
was successful, the LED will blink continuously.
4. The sensor enters sleep mode when not in use. However, the sensor must be "awake" to receive
messages from the controller. To activate "stay-awake mode", remove the front cover. This will wake
up the sensor. Leave the cover off to enable the controller to query the sensor for device specific
information and capabilities.
Federal Communications Commission Statement
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired
operation.
Changes or modifications not expressly approved by Ecolink Intelligent Technology, Inc. can void the
users' authority to operate the equipment.
This device complies with Industry Canada license-exempt RSS standards. Operation is subject
to the following two conditions: (1) this device may not cause interference, and (2) this device
must accept any interference, including interference that may cause undesired operation of the
device.
C'et appareil est conforme la norme d'Industrie Canada exempts de licence RSS. Son fonctionnement est
soumis aux deux conditions suivantes: (1) c'et appareil ne peut pas provoquer d'interférences, et (2) c'et
appareil doit accepter toute interférence, y compris les interférences qui peuvent causer un mauvais
fonctionnement de la dispositif.
Page 2 of 2

Advertisement

loading