Page 3
Conventions • Some models featured in this guide may be unavailable in your country or region. For local sales information, visit http://www.tp-link.com. • The figures in Chapter 2 to Chapter 3 are for demonstration purposes only. Your switch may differ in appearance from that depicted.
*PD is a device powered by a PSE and thus consumes energy. Examples include ■ powering IP telephones, wireless LAN access points, network cameras, network hubs, embedded computers etc. Features For TL-SG1048/TL-SG1024/TL-SG1024D/TL-SG1016/TL-SG1016D/TL-SG1008: Complies with IEEE802.3i, IEEE802.3u, IEEE802.3ab standards ■ 8/16/24/48 10/100/1000Mbps Auto-Sense RJ45 ports supporting Auto-MDI/MDIX ■...
Gigabit Unmanaged Switch TL-SG1024/TL-SG1024D/TL-SG1016/TL-SG1016D/TL-SG1008 supports IEEE802.3x ■ flow control for full-duplex mode and backpressure for half-duplex transfer mode TL-SG1008 supports IEEE802.1p standard ■ Non-blocking switching architecture that forwards and filters packets at full wire-speed ■ for maximum throughput Supports MAC address auto-learning and auto-aging ■...
Page 7
Gigabit Unmanaged Switch LEDs Status Indication The switch is powered on. Power The switch is powered off or power supply is abnormal. Green The corresponding port is running at 1000Mbps. Yellow The corresponding port is running at 10/100Mbps. Link/Act Flashing The corresponding port is transmitting or receiving data.
Page 8
The front panel of TL-SG1016D is shown as the following figure. Figure 1-5 Front Panel of TL-SG1016D LEDs 10/100/1000Mbps RJ45 Port The front panel of TL-SG1008 is shown as the following figure. Figure 1-6 Front Panel of TL-SG1008 TL-SG1008 8-Port Gigabit Switch Power...
Page 9
Gigabit Unmanaged Switch The front panel of TL-SG1008MP is shown as the following figure. Figure 1-7 Front Panel of TL-SG1008MP LEDs 10/100/1000Mbps RJ45 Port and PoE Port LEDs Status Indication On (green) The switch is powered on. Power Flashing (green) Power supply is abnormal.
Page 10
Gigabit Unmanaged Switch The 8 ports also support PoE function which integrates power and data onto one Ethernet cable. Once the device you connect to the switch is identified, the switch will supply power through the PoE port, and then you can use it as a 10/100/1000Mbps Auto-Negotiation RJ45 Ethernet port.
Page 11
The rear panel of TL-SG1016D is shown as the following figure. Figure 1-12 Rear Panel of TL-SG1016D Grounding Power Terminal Socket The rear panel of TL-SG1008 is shown as the following figure. Figure 1-13 Rear Panel of TL-SG1008 Power Grounding Socket Terminal...
Page 12
Gigabit Unmanaged Switch The rear panel of TL-SG1008MP is shown as the following figure. Figure 1-14 Rear Panel of TL-SG1008MP Power Grounding Socket Terminal Power Socket Connect the female connector of the power cord here, and the male connector to the AC (Alternating Current) power outlet.
Gigabit Unmanaged Switch Chapter 2 Installation Package Contents Make sure that the package contains the following items. If any of the listed items is damaged or missing, please contact your distributor. One Switch One Power Cord Two mounting brackets and This Installation Guide the fittings Safety Precautions...
Page 14
Gigabit Unmanaged Switch Site Requirements ■ Temperature/Humidity 40℃ 0℃ Please keep a proper temperature and humidity in the equipment room. Too high/low humidity may lead to bad insulation, electricity leakage, mechanical property changes and corrosions. Too high temperature may accelerate aging of the insulation materials and can thus significantly shorten the service life of the device.
■ Note: For detailed lightning protection measures, please refer to the Lightning Protection Guide from the training center of our website: https://www.tp-link.com/en/configuration-guides/lightning_protection_ guide/?configurationId=2962. Installation Site When installing the device on a rack or a flat workbench, please note the following...
Gigabit Unmanaged Switch Cables ■ Note: These tools are not provided with our product. If needed, please self purchase them. Product Installation Desktop Installation ■ To install the device on the desktop, please follow the steps: 1. Set the device on a flat surface strong enough to support the entire weight of the device with all fittings.
Page 17
Gigabit Unmanaged Switch 3. After the brackets are attached to the device, use suitable screws (not provided) to secure the brackets to the rack, as illustrated in the following figure. Rack Figure 2-3 Rack Installation Caution: Please set 5 to 10cm gaps around the device for air circulation. ■...
Gigabit Unmanaged Switch Chapter 3 Connection Ethernet Port Connect a Ethernet port of the switch to the computer by RJ45 cable as the following figure shows. RJ45 Port RJ45 Cable Figure 3-1 Connecting the RJ45 Port Verify Installation After completing the installation, please verify the following items: There are 5 to 10cm of clearance around the sides of the device for ventilation and the ■...
Initialization For TL-SG1048/TL-SG1024/TL-SG1024D/TL-SG1016/TL-SG1016D/TL-SG1008: After the device is powered on, it begins the Power-On Self-Test. A series of tests run automatically to ensure the device functions properly. During this time, its LED...
Make sure the connected device is turned on and working normally. The cable must be less than 100 meters long (328 feet). For more troubleshooting help, go to: https://www.tp-link.com/en/faqs. ■ To download the latest Firmware, Driver, Utility and User Guide, go to: ■...
Appendix B Specifications Item Content IEEE802.3i, IEEE802.3u, IEEE802.3ab IEEE802.3x (except TL-SG1048) Standards IEEE802.1p (for TL-SG1008MP/TL-SG1008) IEEE802.3af (for TL-SG1008MP), IEEE802.3at (for TL-SG1008MP) 10Base-T UTP/STP of Cat. 3 or above(maximum 100m) 100Base-TX 2-pair UTP/STP of Cat. 5 or above (maximum 100m) Transmission Medium 1000Base-T 4-pair UTP/STP of Cat.
Page 22
FCC STATEMENT This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
Page 23
BSMI Notice 安全諮詢及注意事項 • 請使用原裝電源供應器或只能按照本產品注明的電源類型使用本產品。 • 清潔本產品之前請先拔掉電源線。 請勿使用液體、 噴霧清潔劑或濕布進行清潔。 • 注意防潮, 請勿將水或其他液體潑灑到本產品上。 • 插槽與開口供通風使用, 以確保本產品的操作可靠並防止過熱, 請勿堵塞或覆蓋開口。 • 請勿將本產品置放於靠近熱源的地方。 除非有正常的通風, 否則不可放在密閉位置中。 • 請不要私自打開機殼, 不要嘗試自行維修本產品, 請由授權的專業人士進行此項工作。 • 此為甲類資訊技術設備, 于居住環境中使用時, 可能會造成射頻擾動, 在此種情況下, 使用者會被要求採取某 些適當的對策。 Industry Canada Statement CAN ICES-3 (A)/NMB-3(A) Explanation of the symbols on the product label Symbol Explanation AC voltage...