Download Print this page

Smeg CW350B User Manual page 9

Professional glasswashers

Advertisement

3 DISPLAY
Start button
Bicolor led indictor
L3
MACHINE CONFIGURATION PARAMETERS (Intended for technical personnel, not the user)
Parameter
Description
P0
Drain cycle time
P1
Boiler temperature
P2
Tank temperature
P3
Rinse duration
P4
BOILER STOP option
P5
Brief wash time
P6
Drain with overflow option
P7
Cold rinse option
P8
Regeneration option
P9
Maximum water load duration
P10
H2O Hardness (to be set by the user based on water hardness)
P11
Machine type
P12
Wash number counter
Upon first installation it is possible to perform a series of operations which allow for the personalization of the
dishwasher based on the user's necessities, as well as a test cycle which quickly checks the functionality of all of
the components. To perform these operations it is necessary to set the machine to "programming mode" as
described hereafter
Shut the machine off by pressing
Simultaneously press
With the
button (ahead) and the
Once the parameter to modify has been identified, keep the
setting with the "ahead"
Once the setting has been correctly modified, release the
When finished with the settings turn the machine off and on again by pressing
Note: always turn on the DRAIN PUMP function in machines with Air Tank or Break Tank even if absent.
IN PARAMETERIZATION MODE, IF NO BUTTON IS PRESSED WITHIN 30 SECONDS THE KEYBOARD SHUTS
DOWN AND RETURNS TO ITS OFF STATE.
Can indicate the program which will begin and the boiler/Tank
temperature.
In case of anomalies an error code will be indicated, for example
"E 1"
- Boiler temperature anomaly
- Tank temperature anomaly
- Tank loading anomaly
- Tank draining anomaly
- Boiler anomaly
Initiates the program shown on the display
This led indicates the state of the machine
Green indicates the machine is ready for a new program
Red indicates the machine is busy with an operation
Yellow indicates a break after Tank draining
PARAMETER FUNCTION WITH MACHINE ON
and
until P0 appears on the display
button (back) select the programs
and "back"
buttons
button pressed and modify the required
button
 
Range
Preset
1-5'
1
60-95°C
82
40-65°C
55
10-40''
13
YES/NO
1 YES
60-90
60
YES/NO
1 YES
YES/NO
0 NO
YES/NO
1 YES
1-10'
10
35
15
4
4
YES
1 YES
8

Advertisement

loading