Inspection and preventive maintenance

Rigging part inspection

About this task
For each rigging part, use the
Prerequisite
Perform the inspection in a well-lit environment.
Procedure
1. Check that the rigging part is present.
2. If applicable, disassemble the rigging part from the enclosure or the rigging accessory.
Check that the tethers are intact and safely secured.
3. Inspect the part from every side.
Compare with the reference pictures.
Check for:
• corrosion
• wear and cracks
• bends and dents
• holes
• missing safety cues
• missing or loose fasteners
Replacing screws
If a screw is loose, remove and replace it.
Always use the new screws provided in the KR.
If no new screw is available, add blue threadlocker before reusing the screw.
Do not apply more than the indicated torque.
4. Check the geometry of the part to identify critical deformations.
Place the rigging part on a at surface or hold a level against it.
5. Check the moving parts.
Make sure that the mechanism engages correctly.
What to do next
If a problem is detected, perform the authorized maintenance operations or contact your L-Acoustics representative.