3.5 PRE-INSTALLATION WORKS

The figure shows an example of an automation system, constructed using Nice components.
5
A
A Photocells
B Photocells on column
C Key selector
D Boom gate cubicle
TECHNICAL SPECIFICATIONS OF ELECTRICAL CABLES
Identification
Cable characteristics
no.
GEARMOTOR POWER SUPPLY cable
1 cable 3 x 1.5 mm
1
Maximum length 30 m [note 1]
BLUEBUS cable
1 cable 2 x 0.5 mm
2
Maximum length 20 m [note 2]
KEY SELECTOR cable
2 cables 2 x 0.25 mm
3
Maximum length 30 m
OPEN INPUT cable
1 cable 2 x 0.25 mm
Maximum length 30 m
CLOSE INPUT cable
2 x 0.25 mm
Maximum length 30 m
WARNING LIGHT cable [note 4]
1 cable 2 x 0.5 mm
Maximum length 30 m
ANTENNA cable
Other cables
1 x RG58-type shielded cable
Maximum length 15 m; recommended < 5 m
OPEN BOOM INDICATOR cable [note 4]
1 cable 2 x 0.5 mm
Maximum length 30 m
BOOM LIGHTS cable [note 4]
MASTER/SLAVE cable
1 cable 3 x 1 mm
Maximum length 20 m
6 – ENGLISH
C
B
2
2
2
[note 3]
2
2
2
2
2
2
A
3
These above-mentioned components are positioned according
to a typical standard layout. Using the layout in "Figure 5" as a
reference, define the approximate position in which each com-
ponent of the system will be installed.
Note 1 If the power supply cable is longer than 30 m, a cable
Table 3
with larger cross-sectional area (3 x 2.5 mm
used and a safety earthing system must be installed
near the automation.
Note 2 If the BlueBus cable is longer then 20 m, up to maxi-
mum 40 m, it is necessary to use a cable with a greater
cross-sectional area (2 x 1 mm
Note 3 These two cables can be replaced by a single 4 x 0.5
mm
cable.
2
Note 4 Before making the connection, verify that the output is
programmed on the basis of the device to be connected
(refer to the chapter "PROGRAMMING").
a
The cables used must be suited to the type of envi-
ronment of the installation site.
a
When laying the pipes for routing the electrical ca-
bles, take into account that any water deposits in
the junction boxes may cause the connection pipes
to form condensate inside the control unit, thus
damaging the electronic circuits.
a
Before proceeding with the installation, prepare the
required electrical cables by referring to "Figure 5"
and to that stated in the "TECHNICAL SPECIFICA-
TIONS" chapter.
B
D
2
1
).
2
) must be
2