Technical Specifications - Nice M3BAR Instructions And Warnings For Installation And Use

Table of Contents

Advertisement

11

TECHNICAL SPECIFICATIONS

12
TECHNICAL SPECIFICATIONS
l
All technical specifications stated in this section refer to an ambient temperature of 20°C (± 5°C). Nice S.p.A.
reserves the right to apply modifications to the product at any time when deemed necessary, without altering
its functions and intended use.
TECHNICAL SPECIFICATIONS
Description
Product type
Clear opening (m)
Start peak torque (Nm)
Start peak torque (Nm)
Manoeuvre time (adjustable in sec)
Maximum frequency of operating
cycles/hour at nominal torque (the
control unit limits the cycles to the
maximum shown in Table T3)
Durability
Power supply
Power supply voltage /V1
Maximum power draw at peak (W)
Maximum power at nominal torque
(W)
Insulation class
Emergency power supply
Photovoltaic power supply
FLASH output
LIGHT output
OGI output
Output for warning light / traffic light
on cover
BLUEBUS output
STOP input
Sbs input
OPEN input
CLOSE input
HP SbS input
Radio connector
Radio ANTENNA input
Inputs for metal detectors
Programmable functions
Self-learning functions
Operating temperature
Use in highly acid, saline or
potentially explosive atmosphere
Protection rating
Dimensions and weight
Technical specification
M3BAR
M5BAR
Boom gate for residential use inclusive of electronic control unit
2,32 ÷ 2,82
3,17 ÷ 4,82
100
200
30
70
2,5 - 4
3 - 6
500
350
continuous use
continuous use
Refer to the "Product durability" paragraph
230VC 50/60Hz
230VC 50/60Hz
150
110
40
50
1
With optional accessory PS224
With optional accessory SYKCE
for 1 LUCYB, MLB or MLBT warning light (12 V – 21 W)
for XBA4 "boom lights" optional accessory
for 24 V (max 10 W) indicator light
with XBA7 LED warning light or XBA8 LED traffic light optional accessories
One output with maximum load of 10 BlueBus units
For normally closed or normally open contacts or for 8.2 kΩ fixed resistor contacts with self-
learning (any variation from the memorised status triggers the STOP command)
For normally open contacts
For normally open contacts
For normally open contacts
For normally open contacts
SM connector for SMXI and SMXIS receivers
50 Ω for RG58-type cable or similar
2
Refer to the "PROGRAMMING" chapter and additional settings via the Oview Programming
and Control Unit
Self-learning of the devices connected to the BlueBus output
Self-learning of the type of "STOP" device (Normally Open, Normally Closed contact or 8.2
kΩ resistor)
Learning of the door opening and closing positions
-20°C ÷ 55°C
No
IP54
400x299x1215h mm;
400x299x1215h mm;
80 kg
80 kg
M7BAR
L9BAR
5 ÷ 7
7 ÷ 9
300
400
90
130
6 - 10
8 - 12
200
150
110
160
40
50
400x299x1215h mm;
500x299x1215h mm;
85 kg
98 kg
Table 18
ENGLISH – 43

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

M5barM7barL9bar

Table of Contents