Beko BEKOMAT 33U Instructions For Installation And Operation Manual page 19

Condensate drain
Table of Contents

Advertisement

Terminal assignment of the potential-free contact and of the external test
X 1
X 2
Note:
At a low-voltage supply (< 50 VAC / < 75 VDC), only use a protective extra-low-voltage.
Tighten the threaded cable connection with a slightly sealing effect.
Pos: 58 / Beko Techni s che D ok um ent at i o n/ I nst al l a t i o n/ B EKO M AT/ E- Sch em a @ 0\ m od_12337581781 63_290 1. docx @ 13497 @ @ 1
Electric diagram
Pos: 59 / - - - - Sei t enum br uch - - - - @0\ m od_1157028099015_ 0. docx @ 2903 @ @ 1
BEKOMAT® 33U / 33U CO
X 3
Fault indication/potential-free contact:
X 2.1 n.o.
X 2.2 com.
X 2.3 n.c.
n.c. - com. closed in the event of malfunction or power failure
(closed current principle)
n.o. - com. closed during normal operation
The contacts X2.1 - 2.3 are potential-free.
External test / remote control:
X 3.1 external test (IN1)
X 3.2 GND
Contacts connected = test active = discharge
Contacts open = test inactive
The contacts X 3.1 -3.2 are not potential-free.
Electrical installation
19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bekomat 33u co