Self-Test Failure Led; Operational Status Leds; Summary: Interpreting The Leds - HP 27115A Installation Manual

Fiber-optic link (hp-fl) device adapter for hp 3000 series 900 computer systems
Table of Contents

Advertisement

Self-Test Failure
LED
Operational Status
LEOs
Summary: Interpreting
the
LEOs
The self-test runs when the computer power is switched on or the
PCA
is reset.
The self-test failure LED goes on during execution of the self-test (which takes
less than five seconds), and will go off when the self-test passes.
If
the self-test
fails, the self-test failure LED will remain on, and you must replace the
PCA.
If
the
PCA
self-test completes successfully, the self-test failure LED will turn off
and remain off. Subsequently, under firmware control, the
PCA
will begin
operation. In this mode, the interpretation of the LEDs is summarized in
table 3-1 and described below.
In table 3-1, the bold
type
in the status column shows the acceptable state(s) of
the LED in question. Entries in normal-weight type designate a fault. The
self-test failure LED must be off for this information to be accurate.
Table 3-1. LED Interpretation During Normal Operation
LED
Status
Meaning
(color)
"C"
ofT
PCA
is set up correctly and the remote device is compatible.
Config
Jumper J2 is in the wrong position or the response from
(red)
on
the remote device is incompatible with the
HP-FL
protocol.
ofT
The signal strength and quality are acceptable.
The signal
is
marginal. The brighter the LED appears, the
"S"
flicker
less likely it is that the signal strength will allow successful
Signal
data transfers. See below.
(red)
The signal is lacking or of unacceptable quality:
- There are no transitions on the link.
on
- The phase lock receiver cannot acquire the signal.
- The link error rate exceeds acceptable tolerances.
"R"
ofT
The remote device has correctly identified itself.
Remote
The remote device fails to respond or responds incorrectly
(red)
on
to periodic identification requests.
on
The
PCA
self-test passed - the
PCA
is operational.
"P"
Passed
blinking
The on-board firmware is waiting for an initial connect
(green)
subchannel over the
CIO
bus backplane.
off
The
PCA
is no longer functional.
"A"
blinking The
HP-FL
is transmitting header fields in data frame.
Activity
The
HP-FL
has detected protocol errors or the expected
(green)
off
status information is lacking. The
PCA
is probably faulty.
Troubleshooting and Diagnostics 3-3