Adjusting For Bottled Gas; Adjusting For Natural Gas - Smeg PTSA605-3 Instruction Manual

Smeg gas cooktop instruction manual
Table of Contents

Advertisement

5.2
Undo the screw A and push the support B fully down. Remove the nozzle C with a
spanner and fit the suitable one following the instructions in the tables referring to the
type of gas to be used. The nozzle must not be tightened with a torque of more than 3
Nm. Return the support B to its original position, so that the nozzle C is perfectly
covered. Regulate the air flow by moving the Venturi pipe D until the distance "X" stated
in point "5.4 Adjusting the primary air flow" is obtained and secure it with the screw A.
When the adjustments are complete, restore the seals with wax or an equivalent
material.
Burner
Auxiliary
Semi rapid
Rapid (3)
Rapid (6)
Rapid (7)
WOK double
flame (8)
WOK double
flame (4)
WOK
5.3
The appliance is tested with natural gas at the pressure of 1.0 kPa. To return the appliance
to the condition required to use this type of gas, proceed as described in point "5.2 Adjusting
for bottled gas" but select the nozzles and adjust the primary air flow for natural gas, as
indicated in the table below and in point "5.4 Adjusting the primary air flow".
Burner
Auxiliary
Semi rapid
Rapid (3)
Rapido (6)
Rapid (7)
WOK double
flame (8)
WOK double
flame (4)
WOK
12
Instructions for the Installer

Adjusting for bottled gas

Internal
External
Internal
External

Adjusting for natural gas

Internal
External
Internal
External
ULPG – 2.75 kPa
Nominal gas
Consumption (MJ/h)
4.1
6.0
12.6
11.2
11.2
3.6
15.1
3.6
14.4
15.1
Natural gas – 1.0 kPa
Nominal gas
Consumption (MJ/h)
4.5
6.1
12.6
11.9
10.8
3.6
15.1
3.6
14
15.1
Injector
(mm)
0.54
0.68
0.95
0.85
0.85
0.50
1.05
0.50
0.98
1.05
Injector
(mm)
0.98
1.10
1.60
1.55
1.45
0.85
1.70
0.85
1.65
1.70

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ptsa725x3Ptsa726x5Ptsa727x5

Table of Contents