LG AR-DR11-08A Installation And Operation Manual page 89

Rooftop dedicated outdoor air systems doas 650 to 12,000 cfm
Table of Contents

Advertisement

Table 48: Alarm Data, continued.
Alarm ID
Alarm Screen Line 1
243
Neutral Deck Temp
244
Comp Maint Alarm
245
Supply Air Temperature
246
Space High Static Pres
247 - 254
Liquid Pres Ckt (x)
255
Internal Board Temp
256
Regeneration Fan Run
257 - 264
Water Flow Ckt (x)
265
Pre Cooling Coil Temp
266
Post Cooling Coil Temp
267
BMS Offline
268 - 275
Liquid Temp Ckt (x)
276
Clg Coil Setpt Input
277
Sup Air Setpt Input
278
Cond Circuit (x)
286
Supply Fan
287
Exhaust Fan
288
Generic Fan
289
BACnet License
290
Regen Low Temp
291
Water Leak
292
Oil Level Switch
293
Supply Water Temp 2
294
Return Water Temp 2
295 - 296
Low Suction SH ExV (x)
297 - 298
LOP (x) EVD 1
299 - 300
MOP (x) EVD 1
301 - 302
EEV (x) EVD 1
303 - 304
LowSuct (x) EVD 1
305
High Condensing Temp
306
Suction Press Sens S1
307
Suction Temp Sens S2
308
Probe S3 - Not Used
309
Dschg Temp Sens S4
310
EVD EEPROM Damaged
311
Incomplete Closing EVD
312
Emergency Closing EVD
313
EVD Battery
314
FW Incompatibility
315
EVD Config Error
316
EVD Comm
317
High Discharge Temp
318
Low Discharge Pressure
319
High Suction Pressure
Alarm Screen Line 2
Reset Type
Sensor Value Not Valid
Run Hours Spt Reached
High Limit Shutdown
Shutdown
Sensor Value Not Valid
Exceeds -40F or 158F
Status Not Proven
Flow Switch not made
Sensor Value Not Valid
Sensor Value Not Valid
Watchdog is FALSE
Sensor Value Not Valid
Value is not valid
Value is not valid
Overload Tripped
Overload Tripped
Overload Tripped
Overload Tripped
Not Installed
Check Furnace
Detected
Inverter Compressor
Sensor Value Not Valid
Sensor Value Not Valid
EVD Alarm
Low Operating Pressure
Max Operating Pressure
Motor Alarm
Refrigerant Temp
Sensor Value Not Valid
Sensor Value Not Valid
Sensor Value Not Valid
Sensor Value Not Valid
Call Unison
Replace Battery
Call Unison
EVD is Offline
Inverter Compressor
Auto until Lockout 3x in 1 hr Disable Inverter Circuit Only with Inverter Scroll
Inverter Compressor
Auto until Lockout 3x in 1 hr Disable Inverter Circuit Only with Inverter Scroll
Inverter Compressor
Auto until Lockout 3x in 1 hr Disable Inverter Circuit Only with Inverter Scroll
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG" is a registered trademark of LG Corp.
Lockout
Action Type
Auto
Informational
Manual
Informational
Manual
Shutdown Unit
Manual
Shutdown Unit
Switch to Discharge or
Auto
Auto
Informational
Auto
Disable Regen Control
Disable Compressor
Manual
Auto
Disable PreCooling
Auto
Informational
Auto
Local Control
Switch to Discharge or
Auto
Auto
Informational
Auto
Informational
Disable Compressor
Auto
Auto
Informational
Auto
Informational
Auto
Informational
Auto
Informational
Auto
Informational
Manual
Disable Compressors
Auto
Disable Inverter Circuit
Auto
Disable Compressors
Auto
Disable Compressors
Auto
Disable Inverter Circuit
Auto
Disable Inverter Circuit
Manual
Disable Inverter Circuit
Auto
Disable Inverter Circuit
Auto
Disable Inverter Circuit
Auto
Disable Inverter Circuit
Auto
Disable Inverter Circuit
Auto
Disable Inverter Circuit
Auto
Disable Inverter Circuit
Auto
Disable Inverter Circuit
Auto
Disable Inverter Circuit
Auto
Disable Inverter Circuit
Auto
Disable Inverter Circuit
Auto
Disable Inverter Circuit
Auto
Disable Inverter Circuit
Auto
Disable Inverter Circuit
Auto
Disable Inverter Circuit
CONTROLLER
Alarm Data
Notes
100% Cond Fan
Circuit
100% Cond Fan
Controls Lite - Setpt
Mode
Controls Lite - Setpt
Mode
Circuit
WSHP
WSHP
Only with EVD
Only with EVD
Only with EVD
Only with EVD
Only with EVD
Only with EVD
Only with EVD
Only with EVD
Only with EVD
Only with EVD
Only with EVD
Only with EVD
Only with EVD
Only with EVD
Only with EVD
Only with EVD
Only with EVD