Download Print this page

Adaptation To Different Types Of Gas - Smeg GKC64-3 Instructions For Use Manual

Smeg cooktop instructions for use

Advertisement

Instructions for the installer
5

ADAPTATION TO DIFFERENT TYPES OF GAS

Before performing any cleaning or maintenance work, disconnect the
appliance from the electrical socket.
The hob has been inspected for G25 (2L3B/P) natural gas at a
pressure of 25 mbar. For functioning with other types of gas the
nozzles must be replaced and the primary air adjusted.
To replace the nozzles and regulate the burners, you have to remove
the top as described in the following paragraph.
5.1
Removing the separable control panel (models with
separable control panel)
1.
Remove the knobs and the knob
guard tube "A" by pulling them up;
2.
Use a crosshead screwdriver to
remove the screws and the two
cylindrical supports "B";
3.
Raise the left-hand side of the
control panel slightly and shift it to
the right to remove it completely;
4.
In models with electric hotplate, the
body of the pilot light has to be
removed to free the control panel;
5.2
Removing the hob (models with integrated control
panel)
1.
Remove
the
griddles, the burner caps, the
flame caps and the two rear
plugs;
2.
Remove the screws "A" which
fix the burner supports;
3.
Raise the hob, sliding it off the
ignition
plugs
thermocouples and the gas
tap rods;
5.3
Regulation for LPG
Check that the connection has been made as described in the "Gas
connection" section.
Undo the screw "D" and push the air regulator "C" fully down. Use a
spanner to remove the nozzles "B" and fit those of suitable type
knobs,
the
and/or
the
31

Advertisement

loading

This manual is also suitable for:

Gkc95-3Gke64Gke64x-3Gkr64-3Gkr64a-3Ser64xgnl