SPECIFICATIONS

A.
Table - Unit Data
Model No.
Nominal
Electrical
Capacity
Rating
(BTU HR)
120 Vac
Cooling
60 Hz 1 ph
640312.30X
11,000
640312C35X
11,000
640312.80X
11,000
640312.83X
11,000
640312C85X
11,000
640315.30X
13,500
640315C35X
13,500
640315.80X
13,500
640315.83X
13,500
640315.84X
13,500
640315C85X
13,500
*
For wire length over 24 ft., consult the National Electrical Code for proper sizing.
** Dometic Corporation gives GENERAL guidelines for generator requirements. These guidelines come from experiences
people have had in actual applications. When sizing the generator, the total power usage of your RV must be considered.
Keep in mind generators lose power at high altitudes and from lack of maintenance.
*** CIRCUIT PROTECTION: Time Delay Fuse or Circuit Breaker Required.
B.

Roof Requirements

A 14-1/4" x 14-1/4" (±1/8") square opening (hereinafter referred to as "roof opening") is required for installing this
unit. This opening is part of the return air system of the unit and MUST be finished in accordance with NFPA 1192.
Roof construction with rafters/joists support frames on a minimum of 16 inch centers.
Minimum of 2 inches and maximum of 5-1/2 inches distance between roof to ceiling of RV.
C.
Table - Air Distribution Duct Sizing & Design
Roof Cavity Depth
Duct Cross Sectional Area
*Duct Size
Depth
Width
Total Duct Length
Duct Length (short run)
Register Requirements per A/C Unit
Number Required
Register Free Air Area
Distance From Duct End
Distance From Elbow
Total System Static Air Pressure
Blower at High Speed,
Filter & Grill In Place
*Duct sizes listed are inside dimensions. Duct material MUST meet or exceed any agency or RVIA Standard in effect at the
time the RV is manufactured.
Compressor
Compressor
Fan Motor
Rated Load
Locked
Rated Load
Amps
Rotor
Amps
Amps
10.5
53.0
3.5
10.5
53.0
3.5
11.5
53.0
2.6
12.5
63.0
2.6
11.5
53.0
2.6
12.5
61.0
3.5
12.5
61.0
3.5
12.6
63.0
2.6
12.5
63.0
2.6
12.5
63.0
3.5
12.6
63.0
2.6
Return Air Grille Kit
3105007.XXX
3105935.XXX
2.0 In. Min. - 5-1/2 In. Max.
21.0 Sq. In. Min.
1-1/2 In. Min. - 2-1/2 In. Max.
7.0 In. Min. - 10.0 In. Max.
15.0 Ft. Min. - 40.0 Ft. Max.
1/3 Total Duct Length
4 Min. - 8 Max.
14.0 Sq. In.
5.0 In. Min. - 8.0 In. Max.
15.0 In.
0.12 - 0.65 In W.C.
Fan Motor
Refrigerant
Minimum
Locked
R-410A
Wire Size*
Rotor
(oz)
12 AWG
Amps
Copper
Up to 24'
10.0
19.0
10.0
19.0
8.5
20.0
8.5
18.0
8.5
20.0
10.0
17.5
10.0
17.5
8.5
18.0
8.5
19.0
8.5
19.0
8.5
18.0
4
AC Circuit
Minimum
Protection
Generator
***Installer
Size**
Supplied
1 Unit / 2 Units
20 Amp
3.5 kW / 5.0 kW
20 Amp
3.5 kW / 5.0 kW
20 Amp
3.5 kW / 5.0 kW
20 Amp
3.5 kW / 5.0 kW
20 Amp
3.5 kW / 5.0 kW
20 Amp
3.5 kW / 5.0 kW
20 Amp
3.5 kW / 5.0 kW
20 Amp
3.5 kW / 5.0 kW
20 Amp
3.5 kW / 5.0 kW
20 Amp
3.5 kW / 5.0 kW
20 Amp
3.5 kW / 5.0 kW