Table 6. Description of wiring terminal connections for
PUL6438S, PVL6436AS, and PVL6438NS.
Terminal
Label
INPUT POWER & GROUND
1
24 Vac
2
24 Vac COM
3
EGND
4
SHLD
5
SBUS 1
6
SBUS 2
NETWORK CONNECTIONS
7
NET-1
8
NET-2
DIGITAL OUTPUTS
9
DO-1
10
DO-2
11
COM
12
DO-3
13
DO-4
14
COM
15
DO-5
16
DO-6
17
COM
18
DO-7
19
DO-8
20
COM
ANALOG OUTPUTS
21
AO-1
22
COM
23
AO-2
24
AO-3
25
COM
DIGITAL INPUTS
26
DI-1
27
DI-2
28
COM
29
DI-3
30
DI-4
ATTACHED DEVICE(S) POWER
31
20 Vdc
UNIVERSAL INPUTS
32
UI-1
33
COM
34
UI-2
35
UI-3
36
COM
37
UI-4
38
UI-5
39
COM
40
UI-6
a
For the PVL6436AS controller ONLY, terminals 18, 19, and 20 (DO7,
DO8, & COM) are not present. The actuator is internally hardwired to
these terminals.
b
Analog outputs may be configured as digital outputs and operate as fol-
lows:
– False (0%) produces 0 Vdc, (0 mA)
– True (100%) produces the maximum 11 Vdc (22 mA)
c
Digital inputs: Open circuit = False; Closed circuit = True
Connection
24 Vac Power
24 Vac Power
Earth Ground
Shield
Sylk
Sylk
L
W
® communications
ON
ORKS
L
W
® communications
ON
ORKS
a
Digital Output
Digital Output
Common
Digital Output
Digital Output
Common
Digital Output
Digital Output
Common
Digital Output
Digital Output
Common
b
Analog Output
Common
Analog Output
Analog Output
Common
c
Digital Input
Digital Input
Common
Digital Input
Digital Input
20 Vdc Power
Universal Input
Common
Universal Input
Universal Input
Common
Universal Input
Universal Input
Common
Universal Input
SPYDER® LON PROGRAMMABLE, VAV/UNITARY CONTROLLERS
Table 7. Description of wiring terminal connections for
PUL1012S, PUL4024S, PVL0000AS, PVL4022AS, and
Terminals,
Terminals,
PUL4024S,
PVL4024NS
PVL4022AS
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
NA
10
NA
11
NA
12
NA
13
13
14
14
15
15
16
16
17
17
18
18
19
19
20
20
21
21
22
22
23
23
24
24
a
For the PVL0000AS and PVL4022AS controllers, DO3 and DO4 are
internally hardwired to the actuator.
b
Digital inputs: Open circuit = False; Closed circuit = True
c
Analog outputs may be configured as digital outputs and operate as fol-
lows:
- False (0%) produces 0 Vdc, (0 mA)
- True (100%) produces the maximum 11 Vdc (22 mA)
b
Digital inputs: Open circuit = False; Closed circuit = True
d
UI-1* is a hybrid input. It can be configured as either a DI (fast digital
pulse meter) or a UI.
IMPORTANT
If the controller is not connected to a good earth
ground, the controller's internal transient protection
circuitry is compromised and the function of protect-
ing the controller from noise and power line spikes
cannot be fulfilled. This could result in a damaged cir-
cuit board and require replacement of the controller.
Refer to installation diagrams for specific wiring.
13
PVL4024NS.
Terminals,
Terminals,
a
a
PUL1012S
PVL0000AS
Label
INPUT POWER & GROUND
1
1
24 Vac
2
2
24 Vac
COM
3
3
EGND
4
4
20 Vdc
5
5
SBUS 1 Sylk
6
6
SBUS 2 Sylk
NETWORK CONNECTIONS
7
7
NET-1
8
8
NET-2
b
DIGITAL OUTPUTS
NA
NA
DO-3
NA
NA
COM
NA
NA
DO-4
NA
NA
COM
13
NA
DO-1
14
NA
DO-2
15
NA
COM
c
ANALOG OUTPUTS
16
NA
AO-1
17
NA
COM
NA
NA
AO-2
UNIVERSAL INPUTS
19
NA
UI-1*
20
NA
COM
NA
NA
UI-2
NA
NA
UI-3
NA
NA
COM
NA
NA
UI-4
Connection
24 Vac Power
24 Vac Power
Earth Ground
20 Vdc Power
LonWorks®
communications
LonWorks®
communications
Digital Output
Common
Digital Output
Common
Digital Output
Digital Output
Common
Analog Output
Common
Analog Output
d
Universal Input
Common
Universal Input
Universal Input
Common
Universal Input
63-2685—03