Selecting a Site

Switch units can be mounted in a standard 19-inch equipment rack or on a
flat surface. Be sure to follow the guidelines below when choosing a
location.
The site should:
-
-
-
-
-
Make sure twisted-pair cable is always routed away from power lines,
fluorescent lighting fixtures and other sources of electrical
interference, such as radios and transmitters.
Make sure that the unit is connected to a separate grounded power
outlet that provides 100 to 240 VAC, 50 to 60 Hz, is within 2.44 m
(8 feet) of each device and is powered from an independent circuit
breaker. As with any equipment, using a filter or surge suppressor is
recommended.
NSTALLING THE
be at the center of all the devices you want to link and near a
power outlet.
be able to maintain its temperature within 0 to 40 °C (32 to
104 °F) and its humidity within 10% to 90%, non-condensing
provide adequate space (approximately two inches) on all sides for
proper air flow
be accessible for installing, cabling and maintaining the devices
allow the status LEDs to be clearly visible