  • Page 1 INSTALLATION & OPERATION MANUAL VTC1015 Series Voltage Converter An ISO9001 Registered Company Battery Chargers • Inverters • Power Supplies • Voltage Converters 8128 River Way, Delta B.C. V4G 1K5 Canada T. 604.946.9981 F. 604.946.9983 TF. 800.668.3884 (US/CANADA) www.analyticsystems.com...
  • Page 2 Copyright (2005-2016) Analytic Systems Ware (1993) Ltd. Revised - Feb 2, 2018...
  • Page 3: Important Safety Instructions

    Never allow battery acid to drip onto the voltage converter. Medical Equipment Notice Analytic Systems does not recommend the use of their products in life support applications where failure or malfunction of this product can be reasonable expected to cause the failure of the life support device or to significantly affect its safety or effectiveness.
  • Page 4 Introduction The VTC1015 model voltage converter supplies up to 1000 watts of power to a connected load, converting an input of 24, 36, 48 or 72 VDC to a 12, 24 or 24 VDC output. The unit features full electrical isolation between the input and output to be compatible with positive or negative grounded systems.
  • Page 5: Main Parts

    Chassis Grounding Stud Box Contents The box you have received should contain the following: • One VTC1015 Voltage Converter • This manual • One Warranty Card If anything is missing or damaged please contact your dealer or Analytic Systems for a replacement...
  • Page 6: Installation

    Installation MOUNTING Mount the unit in a DRY location. Allow at least 4 inches of clearance around it for adequate cooling. INPUT CONNECTION The unit is equipped with 3 foot long (1m) power leads as a DC input connection. This should normally be adequate to connect to a source of power.
  • Page 7: Operation

    Operation This unit is designed for simple and intuitive operation. Before you use the unit, make sure the load and power source are correctly connect as shown under Installation TURNING THE UNIT ON AND OFF To turn the converter on, press the On/Off toggle switch on the top The Output ON LED will start glowing green, indicating that the outputs are energized.
  • Page 8: Remote Control Option

    Remote Control Option IMPORTANT: This remote is to be used only on Voltage Converters manufactured by Analytic Systems. A remote control panel may be connected to the voltage converter using a 9-pin D-connector that attaches to the side of the voltage converter. The remote control panel and D connector are part of the remote control option.
  • Page 9 Load Sharing (Option D) The Load Sharing Option (Option D) allows the unit to be connected in parallel with other voltage converter to power a single load. To accommodate this function, special output isolation diodes are present in the unit to prevent current from back feeding into the unit. In addition, the peak current is lowered to the continuous rating for safety purposes.
  • Page 10 Battery Backup (Option B) The Battery Backup Option allows the unit to switch to using a connected battery as a power source in the event of external power failure. The DC power output normally supplies the load while the battery is maintained at full charge by a 1A trickle charger built into the unit.
  • Page 11: Troubleshooting

    Troubleshooting This unit provides LED indicators and a buzzer to help diagnose any problems. The unit should sound the buzzer to alert you prior to shutting itself down. You should immediately check the indicators to determine the cause of the shutdown. SYMPTOMS CAUSE Overload LED is glowing The current demanded by the load has exceeded the maximum...
  • Page 12: Specifications

    10.2 lb / 4.7 kg ** Actual startup is at 22, 42, or 67Vdc Input, depending on model * Specifications subjects to change without notice. Designed and manufactured by: ANALYTIC SYSTEMS WARE (1993) LTD. 8128 River Way p. 604.946.9981 f. 604.946.9983 Delta, BC V4G 1K5 Canada tf.
  • Page 13: Limited Warranty

    2 Years from date of manufacture for non-standard or OEM products 1 Year from date of manufacture for encapsulated products. 3. Analytic Systems will determine eligibility for warranty from the date of purchase shown on the warranty card when returned within 30 days, or...
  • Page 14 DESIGNED AND MANUFACTURED BY 800-668-3884 604-946-9983 sales@analyticsystems.com www.AnalyticSystems.com Battery Chargers • Inverters • Power Supplies • Voltage Converters 8128 River Way Delta, BC V4G 1K5 | Canada Register Products Online | www.analyticsystems.com/support/warranty-registration...